Abstract
Abstract
Background
The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure.
Methods
Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices.
Results
50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket.
Discussion
There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.
Funder
Engineering and Physical Sciences Research Council
Publisher
Springer Science and Business Media LLC
Subject
Health Informatics,Rehabilitation
Reference82 articles.
1. Pirouzi G, Abu Osman NA, Eshraghi A, Ali S, Gholizadeh H, Wan Abas WA. Review of the socket design and interface pressure measurement for transtibial prosthesis. ScientificWorldJournal. 2014;2014:849073.
2. Kenney M, Ramirez, Kalibbala, Ackers L, Ssekitoleko R. Prosthetics services in Uganda—a series of studies to inform the design of a low cost, but fit-for-purpose, body-powered prosthesis. 2019.
3. Paternò L, Ibrahimi M, Gruppioni E, Menciassi A, Ricotti L. Sockets for limb prostheses: a review of existing technologies and open challenges. IEEE Trans Biomed Eng. 2018;65(9):1996–2010.
4. Andrysek J. Lower-limb prosthetic technologies in the developing world: a review of literature from 1994–2010. Prosthet Orthot Int. 2010;34(4):378–98.
5. Sanders JE, Fatone S. Residual limb volume change: systematic review of measurement and management. J Rehabil Res Dev. 2011;48(8):949.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献