Eye-tracking control of an adjustable electric bed: construction and validation by immobile patients with multiple sclerosis

Author:

Kopecek Martin,Kremlacek Jan

Abstract

Abstract Background In severe conditions of limited motor abilities, frequent position changes for work or passive and active rest are essential bedside activities to prevent further health complications. We aimed to develop a system using eye movements for bed positioning and to verify its functionality in a control group and a group of patients with significant motor limitation caused by multiple sclerosis. Methods The eye-tracking system utilized an innovative digital-to-analog converter module to control the positioning bed via a novel graphical user interface. We verified the ergonomics and usability of the system by performing a fixed sequence of positioning tasks, in which the leg and head support was repeatedly raised and then lowered. Fifteen women and eleven men aged 42.7 ± 15.9 years in the control group and nine women and eight men aged 60.3 ± 9.14 years in the patient group participated in the experiment. The degree of disability, according to the Expanded Disability Status Scale (EDSS), ranged from 7 to 9.5 points in the patients. We assessed the speed and efficiency of the bed control and the improvement during testing. In a questionnaire, we evaluated satisfaction with the system. Results The control group mastered the task in 40.2 s (median) with an interquartile interval from 34.5 to 45.5 s, and patients mastered the task in in 56.5 (median) with an interquartile interval from 46.5 to 64.9 s. The efficiency of solving the task (100% corresponds to an optimal performance) was 86.3 (81.6; 91.0) % for the control group and 72.1 (63.0; 75.2) % for the patient group. Throughout testing, the patients learned to communicate with the system, and their efficiency and task time improved. A correlation analysis showed a negative relationship (rho = − 0.587) between efficiency improvement and the degree of impairment (EDSS). In the control group, the learning was not significant. On the questionnaire survey, sixteen patients reported gaining confidence in bed control. Seven patients preferred the offered form of bed control, and in six cases, they would choose another form of interface. Conclusions The proposed system and communication through eye movements are reliable for positioning the bed in people affected by advanced multiple sclerosis. Seven of 17 patients indicated that they would choose this system for bed control and wished to extend it for another application.

Funder

Technology Agency of the Czech Republic

Publisher

Springer Science and Business Media LLC

Subject

Health Informatics,Rehabilitation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3