Prediction of return of spontaneous circulation during cardiopulmonary resuscitation by pulse-wave cerebral tissue oxygen saturation: a retrospective observational study

Author:

Sakaguchi Kento,Takada Masayuki,Takahashi Kazunori,Onodera Yu,Kobayashi Tadahiro,Kawamae Kaneyuki,Nakane Masaki

Abstract

Abstract Background It is difficult to predict the return of spontaneous circulation (ROSC) during cardiopulmonary resuscitation (CPR). Cerebral tissue oxygen saturation during CPR, as measured by near-infrared spectroscopy (NIRS), is anticipated to predict ROSC. General markers of cerebral tissue oxygen saturation, such as the tissue oxygenation index (TOI), mainly reflect venous oxygenation, whereas pulse-wave cerebral tissue oxygen saturation (SnO2), which represents hemoglobin oxygenation in the pulse wave within the cerebral tissue, is an index of arterial and venous oxygenation. Thus, SnO2 may reflect arterial oxygenation to a greater degree than does TOI. Therefore, we conducted this study to verify our hypothesis that SnO2 measured during CPR can predict ROSC. Methods Cardiac arrest patients who presented at the Emergency Department of Yamagata University Hospital in Japan were included in this retrospective, observational study. SnO2 and TOI were simultaneously measured at the patient’s forehead using an NIRS tissue oxygenation monitor (NIRO 200-NX; Hamamatsu Photonics, Japan). We recorded the initial, mean, and maximum values during CPR. We plotted receiver operating characteristic curves and calculated the area under the curve (AUC) to predict ROSC. Results Forty-two patients were included. SnO2 was significantly greater in the ROSC group than in the non-ROSC group in terms of the initial (37.5% vs 24.2%, p = 0.015), mean (44.6% vs 10.8%, p < 0.001), and maximum (79.7% vs 58.4%, p < 0.001) values. Although the initial TOI was not significantly different between the two groups, the mean (45.1% vs 36.8%, p = 0.018) and maximum (71.0% vs 46.3%, p = 0.001) TOIs were greater in the ROSC group than in the non-ROSC group. The AUC was 0.822 for the mean SnO2 (95% confidence interval [CI]: 0.672–0.973; cut-off: 41.8%), 0.821 for the maximum SnO2 (95% CI: 0.682–0.960; cut-off: 70.8%), and 0.809 for the maximum TOI (95% CI: 0.667–0.951; cut-off: 49.3%). Conclusion SnO2 values measured during CPR, including immediately after arrival at the emergency department, were higher in the ROSC group than in the non-ROSC group.

Publisher

Springer Science and Business Media LLC

Subject

Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3