Author:
Scholz Sean S.,Linder Sissy,Latka Eugen,Bartnick Tobias,Karla Daniel,Thaemel Daniel,Wolff Marlena,Sauzet Odile,Rehberg Sebastian W.,Thies Karl-Christian,Jansen Gerrit
Abstract
Abstract
Background
Although airway management for paramedics has moved away from endotracheal intubation towards extraglottic airway devices in recent years, in the context of COVID-19, endotracheal intubation has seen a revival. Endotracheal intubation has been recommended again under the assumption that it provides better protection against aerosol liberation and infection risk for care providers than extraglottic airway devices accepting an increase in no-flow time and possibly worsen patient outcomes.
Methods
In this manikin study paramedics performed advanced cardiac life support with non-shockable (Non-VF) and shockable rhythms (VF) in four settings: ERC guidelines 2021 (control), COVID-19-guidelines using videolaryngoscopic intubation (COVID-19-intubation), laryngeal mask (COVID-19-Laryngeal-Mask) or a modified laryngeal mask modified with a shower cap (COVID-19-showercap) to reduce aerosol liberation simulated by a fog machine. Primary endpoint was no-flow-time, secondary endpoints included data on airway management as well as the participants‘ subjective assessment of aerosol release using a Likert-scale (0 = no release–10 = maximum release) were collected and statistically compared. Continuous Data was presented as mean ± standard deviation. Interval-scaled Data were presented as median and Q1 and Q3.
Results
A total of 120 resuscitation scenarios were completed. Compared to control (Non-VF:11 ± 3 s, VF:12 ± 3 s) application of COVID-19-adapted guidelines lead to prolonged no-flow times in all groups (COVID-19-Intubation: Non-VF:17 ± 11 s, VF:19 ± 5 s;p ≤ 0.001; COVID-19-laryngeal-mask: VF:15 ± 5 s,p ≤ 0.01; COVID-19-showercap: VF:15 ± 3 s,p ≤ 0.01). Compared to COVID-19-Intubation, the use of the laryngeal mask and its modification with a showercap both led to a reduction of no-flow-time(COVID-19-laryngeal-mask: Non-VF:p = 0.002;VF:p ≤ 0.001; COVID-19-Showercap: Non-VF:p ≤ 0.001;VF:p = 0.002) due to a reduced duration of intubation (COVID-19-Intubation: Non-VF:40 ± 19 s;VF:33 ± 17 s; both p ≤ 0.01 vs. control, COVID-19-Laryngeal-Mask (Non-VF:15 ± 7 s;VF:13 ± 5 s;p > 0.05) and COVID-19-Shower-cap (Non-VF:15 ± 5 s;VF:17 ± 5 s;p > 0.05). The participants rated aerosol liberation lowest in COVID-19-intubation (median:0;Q1:0,Q3:2;p < 0.001vs.COVID-19-laryngeal-mask and COVID-19-showercap) compared to COVID-19-shower-cap (median:3;Q1:1,Q3:3 p < 0.001vs.COVID-19-laryngeal-mask) or COVID-19-laryngeal-mask (median:9;Q1:6,Q3:8).
Conclusions
COVID-19-adapted guidelines using videolaryngoscopic intubation lead to a prolongation of no-flow time. The use of a modified laryngeal mask with a shower cap seems to be a suitable compromise combining minimal impact on no-flowtime and reduced aerosol exposure for the involved providers.