Abstract
Background
Surfactants are widely used across the globe both in industrial and consumer products; their biodegradation characteristics are therefore of high importance. Upon entering a wastewater treatment plant (WWTP), the majority of surfactants are aerobically mineralized to CO2 and H2O. However, a small fraction is inevitably left non-degraded and adheres to the remaining sludge. This sludge is usually further treated in anaerobic digester tanks. Assessment of existing methods for determining anaerobic biodegradability has led to the development of a new test method, which is in principle based on the method DIN 38414 part 8. This new test, named the anaerobic biodegradation under sludge digester conditions test (abbreviated to AnBUSDiC test) allows for a quantification of the degradation of surfactants under conditions encountered in the anaerobic digester tank of municipal WWTPs. The AnBUSDiC test has several advantages over existing methods. The main advantage is that it is particularly suitable for surfactants, because the two-step design minimizes possible unspecific digester gas formation caused by the surface activity of the test substances, therefore avoiding false positive results.
Results
In order to further standardize the AnBUSDiC test and gain regulatory acceptance, a ring test was organized involving seven laboratories, and five model surfactants from different surfactant classes (anionic, non-ionic (branched and linear) and amphoteric) plus a positive control, glucose. The AnBUSDiC test produced reliable repeatable results between laboratories; however, some additional modifications were suggested. It was identified that the original test method did not identify a clear endpoint from which a biodegradation value should be taken. It was proposed that a new more concise endpoint be defined in combination with the AnBUSDiC test to allow better comparability between test results.
Conclusions
The inclusion of a second addition of test substance is a major step forward in the elimination of the variability produced by non-specific gas production. With the exception of one anomalous result for linear alkylbenzene sulfonates, for which an explanation can be provided, the AnBUSDiC method appears to provide overall robust and interpretable results.
Publisher
Springer Science and Business Media LLC
Reference11 articles.
1. Berna JL, Cassani G, Hager C-D, Rehman N, Lopez I, Schowanek D, Steber J, Taeger K, Wind T: Anaerobic biodegradation of surfactants – scientific review. Tenside Surf Det 2007,44(6):312–347.
2. OECD Guideline for the Testing of Chemicals: 314: Simulation Tests to Assess the Biodegradability of Chemicals Discharged in Wastewater. Paris: Organization for Economic Co-operation Development; 2008.
3. Fraunhofer Institut UMSICHT: Anaerobic biodegradability of detergent surfactants, anaerobic biodegradability of detergent surfactants. Final Report. Oberhausen, Germany: Fraunhofer Institut UMSICHT; 2003. [http://ec.europa.eu/enterprise/sectors/chemicals/documents/competitiveness/anaerobic_en.htm]
4. DIN 38414, part 8: German Standard Methods for the Examination of Water, Waste Water and Sludge; Sludge and Sediments (Group S): Determination of the Amenability to Anaerobic Digestion (S 8). Berlin: Deutsches Institut Fur Normung E.V. (German National Standard); 1985.
5. Bendt T, Willing A: A new method to determine the anaerobic degradability of surfactants: the AnBUSDiC test. Environ Sci Eur 2012, 24: 28. 10.1186/2190-4715-24-28
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献