Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: a cross sectional study

Author:

Samouda HanenORCID,Langlet Jérémie

Abstract

Abstract Background Bioelectrical impedance analysis (BIA) is a widely used method to assess total body fat (TBF) depots characterising obesity. Automated BIA devices provide an inexpensive and easy assessment of TBF, making them widely available to the general public and healthcare providers without specific qualification to assess body composition. The equations included in the automated BIA devices have been developed in very few specific populations, which means that they are not suitable to assess TBF for everyone and need to be validated before use in other populations. The aim of the present work is to evaluate the accuracy of the automated BIA device Tanita® BC-532 in youth of White European ethnicity, compared with the dual-energy x-ray absorptiometry (DEXA), gold standard measurement of TBF. Methods Total body fat percentage (TBF%) was measured with the BIA device Tanita® BC-532 and DEXA (Hologic® QDR4500W) in 197 youth of White European ethnicity (N = 104 girls), 7-17 years old, and visiting the Diabetes & Endocrinology Care Paediatrics Clinic, Centre Hospitalier de Luxembourg, for overweight or obesity management. Results TBF% evaluated with BIA was significantly correlated with TBF% measured with DEXA in both boys (r Pearson = 0.617) and girls (r Pearson = 0.648) (p <  10− 4). However, the residual mean between the assessment of TBF% by BIA and by DEXA [TBF BIA (%)-TBF DEXA (%)] is extremely high (mean ± standard deviation = 10.52% ± 5.22% in boys, respectively 9.96% ± 4.40% in girls). The maximal absolute residual value is also very high, about 24% in both genders. Conclusions The automated BIA device Tanita® BC-532 appears to be not accurate to assess total body fat in youth with overweight or obesity. There is a need to calibrate the BIA device before its use in the populations where it was not previously validated.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3