Abstract

Abstract Background The rapid and accurate detection of thyroid-stimulating hormone (TSH) receptor antibodies has always been an urgent need for the clinical diagnosis and management of Graves’ disease (GD). We aimed to evaluate the use of an automated thyroid-stimulating immunoglobulin (TSI) bridge immunoassay in the diagnosis of GD and to analyze the relationship between TSI and the degree of hyperthyroidism. Methods A total of 227 new-onset GD patients, 29 Hashimoto thyroiditis, 43 non-autoimmune thyroid diseases and 37 euthyroid controls were consecutively recruited. All participants accepted the measurement of their serum thyroid function and thyroid-associated antibodies, including TSI being measured by an Immulite 2000 bridge immunoassay and TSH receptor autoantibodies (TRAb) being measured by a third-generation Roche electrochemiluminescence immunoassay. The quantitative consistency between the TSI and TRAb detection methods was analyzed by using Passing-Bablok regression and Bland–Altman plots. The diagnostic performance for GD was assessed by receiver operating characteristic (ROC) curve analysis. Results Among 227 GD patients (174 females and 53 males, with a mean age of 39 years), the quantitative TSI was positively correlated with TRAb (r = 0.8099). According to the cut-off values proposed by the manufacturers (TSI: 0.55 IU/L, TRAb: 1.75 IU/L), the positive rates of TSI and TRAb in new-onset GD patients were 96.92% and 95.15%, respectively. Both TSI and TRAb levels positively correlated with FT4 levels (TSI: r = 0.243, TRAb: r = 0.317; all P < 0.001) and FT3 levels (TSI: r = 0.288, TRAb: r = 0.360; all P < 0.001) in new-onset GD patients. The ROC analysis showed that the optimal TSI cut-off value was 0.577 IU/L for GD diagnosis in this Chinese population, with a sensitivity of 96.92% and a specificity of 97.25%, respectively. The optimal TRAb cut-off value of was 1.38 IU/L, with a sensitivity of 96.92% and a specificity of 99.08%. There were no significant differences between the cut-off values obtained through the ROC analysis and those provided by the manufacturer for both TSI and TRAb when calculating their sensitivity and specificity in diagnosing GD. Among the 8 newly diagnosed GD cases with discordant qualitative antibody results, TSI was more likely than TRAb to match the clinical diagnosis of GD (6 TSI-positive vs. 2 TRAb-positive patients). Conclusion The automated TSI bridge immunoassay was positively correlated with thyroxine levels in new-onset GD patients and was more likely to be consistent with the clinical diagnosis of GD than with that of TRAb. The positive Immulite 2000 TSI cut-off value of 0.577 IU/L for GD diagnosis in the Chinese population were close to the value recommended by the manufacturer.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Endocrinology, Diabetes and Metabolism

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3