Author:
Zarkesh Mohammad Reza,Haghjoo Mokaram
Abstract
Abstract
Background
Although the use of a peripherally inserted central catheter (PICC) has many advantages for the treatment of neonates, catheter malposition may result in serious complications that could be life-threatening. We report the case of a 10-day-old neonate with cardiac tamponade secondary to a PICC line who was successfully treated by pericardiocentesis.
Case presentation
An Iranian (Asian) preterm male neonate was born by Cesarean section with a birth weight of 1190 g and a first-minute Apgar score of 7. Based on an increased respiratory distress syndrome (RDS) score from 4 to 7, resuscitation measures and intubation were performed at the neonatal intensive care unit (NICU). On day 3 after birth, a PICC line was inserted for parenteral therapy. A chest X-ray confirmed that the tip of the PICC line was in the appropriate position. Mechanical ventilation was discontinued 72 h post-NICU admission because of the improved respiratory condition. On the day 10 post-NICU admission, he suddenly developed hypotonia, apnea, hypoxia, hypotension, and bradycardia. Resuscitation and ventilation support were immediately started, and inotropic drugs were also given. Emergency echocardiography showed a severe pericardial effusion with tamponade. The PICC line was removed, and urgent pericardiocentesis was carried out. The respiratory situation gradually improved, the O2 saturation increased to 95%, and vital signs remained stable.
Conclusions
Dramatic improvement of the neonate's clinical responses after pericardial drainage and PICC removal were suggestive of PICC displacement, pericardial perforation, and cardiac tamponade.
Funder
Tehran University of Medical Sciences and Health Services
Publisher
Springer Science and Business Media LLC
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献