Non-invasive detection of a femoral-to-radial arterial pressure gradient in intensive care patients with vasoactive agents

Author:

Jacquet-Lagrèze Matthias,Claveau David,Cousineau Julie,Liu Kun Peng,Guimond Jean-Gilles,Aslanian Pierre,Lamarche Yoan,Albert Martin,Charbonney Emmanuel,Hammoud Ali,Kontar Loay,Denault AndréORCID

Abstract

Abstract Background In patient requiring vasopressors, the radial artery pressure may underestimate the true central aortic pressure leading to unnecessary interventions. When using a femoral and a radial arterial line, this femoral-to-radial arterial pressure gradient (FR-APG) can be detected. Our main objective was to assess the accuracy of non-invasive blood pressure (NIBP) measures; specifically, measuring the gradient between the NIBP obtained at the brachial artery and the radial artery pressure and calculating the non-invasive brachial-to-radial arterial pressure gradient (NIBR-APG) to detect an FR-APG. The secondary objective was to assess the prevalence of the FR-APG in a targeted sample of critically ill patients. Methods Adult patients in an intensive care unit requiring vasopressors and instrumented with a femoral and a radial artery line were selected. We recorded invasive radial and femoral arterial pressure, and brachial NIBP. Measurements were repeated each hour for 2 h. A significant FR-APG (our reference standard) was defined by either a mean arterial pressure (MAP) difference of more than 10 mmHg or a systolic arterial pressure (SAP) difference of more than 25 mmHg. The diagnostic accuracy of the NIBR-APG (our index test) to detect a significant FR-APG was estimated and the prevalence of an FR-APG was measured and correlated with the NIBR-APG. Results Eighty-one patients aged 68 [IQR 58–75] years and an SAPS2 score of 35 (SD 7) were included from which 228 measurements were obtained. A significant FR-APG occurred in 15 patients with a prevalence of 18.5% [95%CI 10.8–28.7%]. Diabetes was significantly associated with a significant FR-APG. The use of a 11 mmHg difference in MAP between the NIBP at the brachial artery and the MAP of the radial artery led to a specificity of 92% [67; 100], a sensitivity of 100% [95%CI 83; 100] and an AUC ROC of 0.93 [95%CI 0.81–0.99] to detect a significant FR-APG. SAP and MAP FR-APG correlated with SAP (r2 = 0.36; p < 0.001) and MAP (r2 = 0.34; p < 0.001) NIBR-APG. Conclusion NIBR-APG assessment can be used to detect a significant FR-APG which occur in one in every five critically ill patients requiring vasoactive agents.

Funder

Montreal Heart Institute Foundation

Richard I. Kaufman Endowment Fund in Anesthesia and Critical Care

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3