Gong Youling,Wang Jin,Bai Sen,Jiang Xiaoqin,Xu Feng
Abstract
Abstract
Background
Treatments for cancer spinal metastasis were always palliative. This study was conducted to investigate the safety and effectiveness of IG-IMRT for these patients.
Methods
10 metastatic lesions were treated with conventionally-fractionated IG-IMRT. Daily kilovoltage cone-beam computed tomography (kV-CBCT) scan was applied to ensure accurate positioning. Plans were evaluated by the dose-volume histogram (DVH) analysis.
Results
Before set-up correction, the positioning errors in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes were 0.3 ± 3.2, 0.4 ± 4.5 and -0.2 ± 3.9 mm, respectively. After repositioning, those errors were 0.1 ± 0.7, 0 ± 0.8 and 0 ± 0.7 mm, respectively. The systematic/random uncertainties ranged 1.4–2.3/3.0–4.1 before and 0.1–0.2/0.7–0.8 mm after online set-up correction. In the original IMRT plans, the average dose of the planning target volume (PTV) was 61.9 Gy, with the spinal cord dose less than 49 Gy. Compared to the simulated PTVs based on the pre-correction CBCT, the average volume reduction of PTVs was 42.3% after online correction. Also, organ at risk (OAR) all benefited from CBCT-based set-up correction and had significant dose reduction with IGRT technique. Clinically, most patients had prompt pain relief within one month of treatment. There was no radiation-induced toxicity detected clinically during a median follow-up of 15.6 months.
Conclusion
IG-IMRT provides a new approach to treat cancer spinal metastasis. The precise positioning ensures the implementation of optimal IMRT plan, satisfying both the dose escalation of tumor targets and the radiation tolerance of spinal cord. It might benefit the cancer patient with spinal metastasis.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Oncology
Cited by
34 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献