The application of PET-CT to post-mastectomy regional radiation therapy using a deformable image registration

Author:

Lee Yu Sun,Kim Kyoung Ju,Ahn Seung Do,Choi Eun Kyung,Kim Jong Hoon,Lee Sang-wook,Song Si Yeol,Yoon Sang Min,Kim Young Seok,Park Jin-hong,Cho Byung Chul,Kim Su Ssan

Abstract

Abstract Background To evaluate the utility of the preoperative PET-CT using deformable image registration (DIR) in the treatment of patients with locally advanced breast cancer and to find appropriate radiotherapy technique for further adequate treatment of axillary nodal area. Methods Sixty-five breast cancer patients who had level II, III axillary or supraclavicular lymph node metastasis on 18F-FDG PET-CT and received postoperative radiotherapy after modified radical mastectomy were enrolled. One radiation oncologist contoured normal organs (axillary vessels, clavicular head, coracoids process and humeral head) and involved lymph nodes on PET-CT and simulation CT slices. After contouring, deformable image registration of PET-CT on simulation CT was carried out. To evaluate the performance of the DIR, Dice similarity coefficient (DSC) and Center of mass (COM) were used. We created two plans, one was the historically designed three field plan and the other was the modified plan based on the location of axillary lymph node, and we compared the doses that irradiated the axillary lymph nodes. Results The DSCs for axillary artery, axillary vein, clavicular head, coracoids process and humeral head were 0.43 ± 0.15, 0.39 ± 0.20, 0.85 ± 0.10, 0.72 ± 0.20 and 0.77 ± 0.20, respectively. The distances between the COMs of axillary artery, axillary vein, clavicular head, coracoids process and humeral head in simulation CT and from PET-CT were 13.0 ±7.1, 20.2 ± 11.2, 4.4 ± 6.3, 3.7 ± 6.7, and 9.5 ± 25.0 mm, respectively. In the historically designed plan, only 57.7% of level II lymph nodes received more than 95% of prescribed dose and the coverage was improved to 70.0% with the modified plan (p < 0.01). For level III lymph nodes, the volumes received more than 95% of prescribed dose were similar in both plans (96.8 % vs 97.9%, p = 0.35). Conclusion Deformable image registration of PET-CT on simulation CT was helpful in the identification of the location of the preoperatively involved axillary lymph node. Historically designed three-field plan was not adequate to treat the axillary level II lymph node area. Novel treatment technique based on the location of axillary lymph node from PET-CT using DIR can result in more adequate coverage of nodal area.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Oncology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3