Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16)

Author:

Shah R.ORCID,Finlay A.Y.ORCID,Salek M.S.ORCID,Allen H.,Nixon S.J.,Nixon M.,Otwombe K.ORCID,Ali F.M.ORCID,Ingram J.R.ORCID

Abstract

Abstract Background The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients’ disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC). Methods Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen’s criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM). Results Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = −0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient’s disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16. Conclusions The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3