Impact of air temperature and drug concentration on liquid emission from elastomeric pumps

Author:

Abe Tomoya,Matsuzaka Kazumasa,Nakayama Toshiaki,Otsuka Masanobu,Sagara Atsunobu,Sato Fumiaki,Yumoto Tetsuro

Abstract

Abstract Background Elastomeric pumps (EPs) are devices that allow quantitative and continuous drug administration without the need for electronic control, and they are used by being filled with anticancer agents. Although the package inserts of several manufacturers that provide EPs describe the relationship between the flow rate per unit time and temperature, the solution is only saline solution or 5% glucose solution, and data on anticancer drugs have not been published. In this study, we focused on 5-fluorouracil (5-FU), a drug frequently used in cancer chemotherapy, and examined the effect of changes in standard of EPs and temperature on drug emission. Methods We evaluated the EP data of patients treated with Baxter Infusor® LV5 and SV2.5 in terms of emission rate, relationship between 5-FU prescription amount and emission rate, and relationship between emission rate and monthly air temperature in LV5 and SV2.5. The number of EPs sampled in the study was N = 5708 (n = 2988 for LV5 and n = 2720 for SV2.5). Results In LV5, the emission rate varied from 88 to 97% (median 94.0%), whereas in SV2.5, the emission rate was observed as 97 to 98% (median 97.4%). The 5-FU prescription amount and the emission rate were not correlated in LV5 and SV2.5, respectively (LV5; y = − 0.0015x + 97.305, R2 = 0.0226, SV2.5; y = − 0.001x + 100.25, R2 = 0.0466). LV5 showed a higher emission rate in the months with higher air temperature and a lower emission rate in the month with lower air temperature. In addition, LV5 showed a significant reduction in emission rate compared with SV2.5 in all months (P < 0.001). Conclusions In this study, we clarified that air temperature is an important factor that affects the drug emission of EPs. Therefore, it is necessary to examine the conditions for total fluid volume suitable for the air temperature in each region and to provide sufficient information to patients.

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Pharmacology (nursing)

Reference16 articles.

1. Harmanjeet H, Zaidi STR, Ming LC, Wanandy T, Patel RP. Physicochemical stability of voriconazole in elastomeric devices. Eur J Hosp Pharm. 2018;25:e88–92.

2. Theodorides AA. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate. J Perioper Pract. 2017;27:276–82.

3. Villalba J, Peñalver J, Torner P, Serra M, Planell J. Home-based intravenous analgesia with elastomeric pump as an outpatient procedure for pain control after anterior cruciate ligament repair. Rev Esp Cir Ortop Traumatol. 2018;62:65–70.

4. Chopra A, Hurren J, Szpunar S, Edwin SB. Assessment of postoperative pain control with an elastomeric pain pump following cardiothoracic surgery. Pain Med. 2017;18:1450–4.

5. de Gramont A, Tournigand C, Louvet C, André T, Molitor JL, Raymond E, et al. Oxaliplatin, folinic acid and 5-fluorouracil (folfox) in pretreated patients with metastatic advanced cancer. The GERCOD. Rev Med Interne. 1997;18:769–75.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3