Relationship between coronary high-intensity plaques on T1-weighted imaging by cardiovascular magnetic resonance and vulnerable plaque features by near-infrared spectroscopy and intravascular ultrasound: a prospective cohort study

Author:

Fukase Tatsuya,Dohi TomotakaORCID,Fujimoto Shinichiro,Nishio Ryota,Nozaki Yui O.,Kudo Ayako,Takeuchi Mitsuhiro,Takahashi Norihito,Chikata Yuichi,Endo Hirohisa,Kawaguchi Yuko O.,Doi Shinichiro,Nishiyama Hiroki,Hiki Makoto,Okai Iwao,Iwata Hiroshi,Yokoyama Takayuki,Okazaki Shinya,Miyauchi Katsumi,Daida Hiroyuki,Li Debiao,Xie Yibin,Minamino Tohru

Abstract

Abstract Background This study aimed to compare the coronary plaque characterization by cardiovascular magnetic resonance (CMR) and near-infrared spectroscopy (NIRS)-intravascular ultrasound (IVUS) (NIRS-IVUS), and to determine whether pre–percutaneous coronary intervention (PCI) evaluation using CMR identifies high-intensity plaques (HIPs) at risk of peri-procedural myocardial infarction (pMI). Although there is little evidence in comparison with NIRS-IVUS findings, which have recently been shown to identify vulnerable plaques, we inferred that CMR-derived HIPs would be associated with vulnerable plaque features identified on NIRS-IVUS. Methods 52 patients with stable coronary artery disease who underwent CMR with non-contrast T1-weighted imaging and PCI using NIRS-IVUS were studied. HIP was defined as a signal intensity of the coronary plaque-to-myocardial signal intensity ratio (PMR) ≥ 1.4, which was measured from the data of CMR images. We evaluated whether HIPs were associated with the NIRS-derived maximum 4-mm lipid-core burden index (maxLCBI4mm) and plaque morphology on IVUS, and assessed the incidence and predictor of pMI defined by the current Universal Definition using high-sensitive cardiac troponin-T. Results Of 62 lesions, HIPs were observed in 30 lesions (48%). The HIP group had a significantly higher remodeling index, plaque burden, and proportion of echo-lucent plaque and maxLCBI4mm ≥ 400 (known as large lipid-rich plaque [LRP]) than the non-HIP group. The correlation between the maxLCBI4mm and PMR was significantly positive (r = 0.51). In multivariable logistic regression analysis for prediction of HIP, NIRS-derived large LRP (odds ratio [OR] = 5.41; 95% confidence intervals [CIs] 1.65–17.8, p = 0.005) and IVUS-derived echo-lucent plaque (OR = 5.12; 95% CIs 1.11–23.6, p = 0.036) were strong independent predictors. Furthermore, pMI occurred in 14 of 30 lesions (47%) with HIP, compared to only 5 of 32 lesions (16%) without HIP (p = 0.005). In multivariable logistic regression analysis for prediction of incidence of pMI, CMR-derived HIP (OR = 5.68; 95% CIs 1.53–21.1, p = 0.009) was a strong independent predictor, but not NIRS-derived large LRP and IVUS-derived echo-lucent plaque. Conclusions There is an important relationship between CMR-derived HIP and NIRS-derived large LRP. We also confirmed that non-contrast T1-weighted CMR imaging is useful for characterization of vulnerable plaque features as well as for pre-PCI risk stratification. Trial registration The ethics committee of Juntendo Clinical Research and Trial Center approved this study on January 26, 2021 (Reference Number 20-313).

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3