Abstract
Abstract
Background
Objective assessment of prosthetic paravalvular leak (PVL) is complex and challenging even in transesophageal echocardiography (TEE). Our aim was to assess the value of cardiovascular magnetic resonance (CMR) in quantifying PVL in aortic (AVR) or mitral valve (MVR) replacement.
Methods
Thirty-one patients (62 ± 15.1 years, 63% males) with a preliminary diagnosis of significant PVL (AVR, n-23; MVR, n = 8) were recruited. The TEE PVL grading was based on the semi-quantitative (SQ) TEE according to the VARC II PVL classification (%PVL: mild < 10%; moderate 10%–30%; severe > 30%). Non-contrast CMR studies were acquired at 1.5 T with a quantitative approach (phase-contrast velocity encoded imaging). The CMR PVL severity was classified according to regurgitant fraction (RF: (1) mild ≤ 20%, (2) moderate 21%–39%, or (3) severe ≥ 40%).
Results
All patients revealed symptoms of heart failure (71%: New York Heart Association [NYHA] II; 91%: N-terminal pro-B-type natriuretic peptide [NT-proBNP] > 150 pg/ml) and typical cardiovascular disease risk factors. The SQ-TEE results revealed several categories: (1) mild (n = 5; 16%), (2) moderate (n = 21; 67%), and (3) severe (n = 5; 16%) PVL. However, CMR PVL RF reclassified the severity of PVL: (1) mild to moderate (in 80%), (2) moderate to severe (in 47%), and (3) severe to moderate (in 40%). The receiver operating characteristic analysis showed that SQ-TEE and CMR PVL-vol and -RF predicted the upper tertile of NT-proBNP (> 2000 pg/ml) with the best sensitivity for CMR parameters.
Conclusion
The SQ-TEE showed moderate agreement with CMR and underestimated a considerable number of AVR or MVR-PVL.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Reference30 articles.
1. Hammermeister K, Sethi GK, Henderson WG, Grover FL, Oprian C, Rahimtoola SH. Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the veterans affairs randomized trial. J Am Coll Cardiol. 2000;36:1152–8.
2. Ionescu A, Fraser AG, Butchart EG. Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography. Heart. 2003;89:1316–21.
3. Cohen H, Kronzon I, Perk G, Fontana GP, Ruiz CE. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013;34:638–48.
4. Emery RW, Krogh CC, McAdams S, Emery AM, Holter AR. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St Jude medical prosthesis. J Heart Valve Dis. 2010;19:473–84.
5. Altiok E, Frick M, Meyer ChG, Al Ateah G, Napp A, Kirschfink AM, et al. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2014;113:1859–66.
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献