Abstract
Abstract
Purpose
To develop a partially interpretable neural network for joint suppression of banding and flow artifacts in non-phase-cycled bSSFP cine imaging.
Methods
A dual-stage neural network consisting of a voxel-identification (VI) sub-network and artifact-suppression (AS) sub-network is proposed. The VI sub-network provides identification of artifacts, which guides artifact suppression and improves interpretability. The AS sub-network reduces banding and flow artifacts. Short-axis cine images of 12 frequency offsets from 28 healthy subjects were used to train and test the dual-stage network. An additional 77 patients were retrospectively enrolled to evaluate its clinical generalizability. For healthy subjects, artifact suppression performance was analyzed by comparison with traditional phase cycling. The partial interpretability provided by the VI sub-network was analyzed via correlation analysis. Generalizability was evaluated for cine obtained with different sequence parameters and scanners. For patients, artifact suppression performance and partial interpretability of the network were qualitatively evaluated by 3 clinicians. Cardiac function before and after artifact suppression was assessed via left ventricular ejection fraction (LVEF).
Results
For the healthy subjects, visual inspection and quantitative analysis found a considerable reduction of banding and flow artifacts by the proposed network. Compared with traditional phase cycling, the proposed network improved flow artifact scores (4.57 ± 0.23 vs 3.40 ± 0.38, P = 0.002) and overall image quality (4.33 ± 0.22 vs 3.60 ± 0.38, P = 0.002). The VI sub-network well identified the location of banding and flow artifacts in the original movie and significantly correlated with the change of signal intensities in these regions. Changes of imaging parameters or the scanner did not cause a significant change of overall image quality relative to the baseline dataset, suggesting a good generalizability. For the patients, qualitative analysis showed a significant improvement of banding artifacts (4.01 ± 0.50 vs 2.77 ± 0.40, P < 0.001), flow artifacts (4.22 ± 0.38 vs 2.97 ± 0.57, P < 0.001), and image quality (3.91 ± 0.45 vs 2.60 ± 0.43, P < 0.001) relative to the original cine. The artifact suppression slightly reduced the LVEF (mean bias = -1.25%, P = 0.01).
Conclusions
The dual-stage network simultaneously reduces banding and flow artifacts in bSSFP cine imaging with a partial interpretability, sparing the need for sequence modification. The method can be easily deployed in a clinical setting to identify artifacts and improve cine image quality.
Funder
National Natural Science Foundation of China
Shanghai Science and Technology Development Foundation
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology