Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes

Author:

Castellanos Daniel A.ORCID,Ahmad Sidra,St. Clair Nicole,Sleeper Lynn A.,Lu Minmin,Schidlow David N.,Rathod Rahul H.,Yin Suellen M.,Esch Jesse J.,Annese David,Powell Andrew J.,Quiñonez Luis,Shaikh Raja,Ghelani Sunil J.

Abstract

Abstract Background Lymphatic complications are common in patients with Fontan circulation. Three-dimensional balanced steady-state free precession (3D bSSFP) angiography by cardiovascular magnetic resonance (CMR) is widely used for cardiovascular anatomical assessment. We sought to determine the frequency of thoracic duct (TD) visualization using 3D bSSFP images and assess whether TD characteristics are associated with clinical outcomes. Methods This was a retrospective, single-center study of patients with Fontan circulation who underwent CMR. Frequency matching of age at CMR was used to construct a comparison group of patients with repaired tetralogy of Fallot (rTOF). TD characteristics included maximum diameter and a qualitative assessment of tortuosity. Clinical outcomes included protein-losing enteropathy (PLE), plastic bronchitis, listing for heart transplantation, and death. A composite outcome was defined as presence of any of these events. Results The study included 189 Fontan patients (median age 16.1 years, IQR 11.0–23.2 years) and 36 rTOF patients (median age 15.7 years, IQR 11.1–23.7 years). The TD diameter was larger (median 2.50 vs. 1.95 mm, p = 0.002) and more often well visualized (65% vs. 22%, p < 0.001) in Fontan patients vs. rTOF patients. TD dimension increased mildly with age in Fontan patients, R = 0.19, p = 0.01. In Fontan patients, the TD diameter was larger in those with PLE vs. without PLE (age-adjusted mean 4.11 vs. 2.72, p = 0.005), and was more tortuous in those with NYHA class ≥ II vs. class I (moderate or greater tortuosity 75% vs. 28.5%, p = 0.02). Larger TD diameter was associated with a lower ventricular ejection fraction that was independent of age (partial correlation = − 0.22, p = 0.02). More tortuous TDs had a higher end-systolic volume (mean 70.0 mL/m2 vs. 57.3 mL/m2, p = 0.03), lower creatinine (mean 0.61 mg/dL vs. 0.70 mg/dL, p = 0.04), and a higher absolute lymphocyte count (mean 1.80 K cells/µL vs. 0.76 K cells/µL, p = 0.003). The composite outcome was present in 6% of Fontan patients and was not associated with TD diameter (p = 0.50) or tortuosity (p = 0.09). Conclusions The TD is well visualized in two-thirds of patients with Fontan circulation on 3D-bSSFP images. Larger TD diameter is associated with PLE and increased TD tortuosity is associated with an NYHA class ≥ II.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3