Reference data for left ventricular filling and atrial function in children using cardiovascular magnetic resonance

Author:

Henderson Christopher C.,George-Durrett Kristen,Kikano Sandra,Slaughter James C.,Chew Joshua D.,Parra David,Weiner Jeffrey,Soslow JonathanORCID

Abstract

Abstract Background  Diastolic dysfunction is associated with morbidity and mortality in multiple pediatric disease processes. Cardiovascular magnetic resonance (CMR) provides a non-invasive method of studying left ventricular (LV) diastolic dysfunction through the assessment of LV filling curves and left atrial (LA) volume and function. However, there are no normative data for LV filling curves and the standard method is time-intensive. This study aims to compare an alternate, more rapid method of obtaining LV filling curves to standard methodology and report normative CMR diastolic function data for LV filling curves and LA volumes and function. Methods  Ninety-six healthy pediatric subjects (14.3 ± 3.4 years) with normal CMR defined by normal biventricular size and systolic function without late gadolinium enhancement were included. LV filling curves were generated by removing basal slices without myocardium present throughout the cardiac cycle and apical slices with poor endocardial delineation (compressed method), then re-generated including every phase of myocardium from apex to base (standard method). Indices of diastolic function included peak filling rate and time to peak filling. Systolic metrics included peak ejection rate and time to peak ejection. Both peak ejection and peak filling rates were indexed to end-diastolic volume. LA maximum, minimum and pre-contraction volumes were calculated using a biplane method. Inter-and intra-observer variability were assessed with intraclass correlation coefficient. Multivariable linear regression was used to assess the effects of body surface area (BSA), gender and age on metrics of diastolic function. Results  BSA had the largest effect on LV filling curves. Normal LV filling data are reported for both compressed and standard methods. The time to perform the compressed method was significantly shorter than the standard method (median 6.1 min vs. 12.5 min, p < 0.001). Both methods had strong to moderate correlation for all metrics. Intra-observer reproducibility was moderate to high for all LV filling and LA metrics except for time to peak ejection and peak filling. Conclusions  We report reference values for LV filling metrics and LA volumes. The compressed method is more rapid and produces similar results to standard methodology, which may facilitate the use of LV filling in clinical CMR reporting.

Funder

National Center for Advancing Translational Sciences

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3