On the optimal temporal resolution for phase contrast cardiovascular magnetic resonance imaging: establishment of baseline values

Author:

Santini FrancescoORCID,Pansini Michele,Hrabak-Paar Maja,Yates Denise,Langenickel Thomas H.,Bremerich Jens,Bieri Oliver,Schubert Tilman

Abstract

Abstract Background The aim of this study is to quantify the frequency content of the blood velocity waveform in different body regions by means of phase contrast (PC) cardiovascular magnetic resonance (CMR) and Doppler ultrasound. The highest frequency component of the spectrum is inversely proportional to the ideal temporal resolution to be used for the acquisition of flow-sensitive imaging (Shannon-Nyquist theorem). Methods Ten healthy subjects (median age 33y, range 24–40) were scanned with a high-temporal-resolution PC-CMR and with Doppler ultrasound on three body regions (carotid arteries, aorta and femoral arteries). Furthermore, 111 patients (median age 61y) with mild to moderate arterial hypertension and 58 patients with aortic aregurgitation, atrial septal defect, or repaired tetralogy of Fallot underwent aortic CMR scanning. The frequency power distribution was calculated for each location and the maximum frequency component, fmax, was extracted and expected limits for the general population were inferred. Results In the healthy subject cohort, significantly different fmax values were found across the different body locations, but they were nonsignificant across modalities. No significant correlation was found with heart rate. The measured fmax ranged from 7.7 ± 1.1 Hz in the ascending aorta, up to 12.3 ± 5.1 Hz in the femoral artery (considering PC-CMR data). The calculated upper boundary for the general population ranged from 11.0 Hz to 27.5 Hz, corresponding to optimal temporal resolutions of 45 ms and 18 ms, respectively. The patient cohort exhibited similar values for the frequencies in the aorta, with no correlation between blood pressure and frequency content. Conclusions The temporal resolution of PC-CMR acquisitions can be adapted based on the scanned body region and in the adult population, should approach approximately 20 ms in the peripheral arteries and 40 ms in the aorta. Trial registration This study presents results from a restrospective analysis of the clinical study NCT01870739 (ClinicalTrials.gov).

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3