Modified cardiovascular SOFA score in sepsis: development and internal and external validation
-
Published:2022-08-22
Issue:1
Volume:20
Page:
-
ISSN:1741-7015
-
Container-title:BMC Medicine
-
language:en
-
Short-container-title:BMC Med
Author:
Lee Hui Jai,Ko Byuk Sung,Ryoo Seung Mok,Han Eunah,Suh Gil Joon,Choi Sung-Hyuk,Chung Sung Phil,Lim Tae Ho,Kim Won Young,Kwon Woon Yong,Hwang Sung Yeon,Jo You Hwan,Shin Jonghwan,Shin Tae Gun,Kim Kyuseok,Choi Sangchun,Chung Tae Nyoung,Lee Jae Hyuk,Kim Kyung Su,Park Yoo Seok,Yoon Young-Hoon,Choi Han Sung,Han Kap Su,Kang GuHyun,Kim Youn-Jung,Cho Hanjin,
Abstract
Abstract
Background
The Sepsis-3 criteria introduced the system that uses the Sequential Organ-Failure Assessment (SOFA) score to define sepsis. The cardiovascular SOFA (CV SOFA) scoring system needs modification due to the change in guideline-recommended vasopressors. In this study, we aimed to develop and to validate the modified CV SOFA score.
Methods
We developed, internally validated, and externally validated the modified CV SOFA score using the suspected infection cohort, sepsis cohort, and septic shock cohort. The primary outcome was 28-day mortality. The modified CV SOFA score system was constructed with consideration of the recently recommended use of the vasopressor norepinephrine with or without lactate level. The predictive validity of the modified SOFA score was evaluated by the discrimination for the primary outcome. Discrimination was assessed using the area under the receiver operating characteristics curve (AUC). Calibration was assessed using the calibration curve. We compared the prognostic performance of the original CV/total SOFA score and the modified CV/total SOFA score to detect mortality in patients with suspected infection, sepsis, or septic shock.
Results
We identified 7,393 patients in the suspected cohort, 4038 patients in the sepsis cohort, and 3,107 patients in the septic shock cohort in seven Korean emergency departments (EDs). The 28-day mortality rates were 7.9%, 21.4%, and 20.5%, respectively, in the suspected infection, sepsis, and septic shock cohorts. The model performance is higher when vasopressor and lactate were used in combination than the vasopressor only used model. The modified CV/total SOFA score was well-developed and internally and externally validated in terms of discrimination and calibration. Predictive validity of the modified CV SOFA was significantly higher than that of the original CV SOFA in the development set (0.682 vs 0.624, p < 0.001), test set (0.716 vs 0.638), and all other cohorts (0.648 vs 0.557, 0.674 vs 0.589). Calibration was modest. In the suspected infection cohort, the modified model classified more patients to sepsis (66.0 vs 62.5%) and identified more patients at risk of septic mortality than the SOFA score (92.6 vs 89.5%).
Conclusions
Among ED patients with suspected infection, sepsis, and septic shock, the newly-developed modified CV/total SOFA score had higher predictive validity and identified more patients at risk of septic mortality.
Funder
National Research Foundation of Korea
Publisher
Springer Science and Business Media LLC
Reference41 articles.
1. Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, Bellomo R, Bernard GR, Chiche JD, Coopersmith CM, et al. The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). JAMA. 2016;315(8):801–10. 2. Rudd KE, Johnson SC, Agesa KM, Shackelford KA, Tsoi D, Kievlan DR, Colombara DV, Ikuta KS, Kissoon N, Finfer S, et al. Global, regional, and national sepsis incidence and mortality, 1990–2017: analysis for the Global Burden of Disease Study. Lancet. 2020;395(10219):200–11. 3. Vincent JL, Sakr Y, Singer M, Martin-Loeches I, Machado FR, Marshall JC, Finfer S, Pelosi P, Brazzi L, Aditianingsih D, et al. Prevalence and outcomes of infection among patients in intensive care units in 2017. JAMA. 2020;323(15):1478–87. 4. Reinhart K, Daniels R, Kissoon N, Machado FR, Schachter RD, Finfer S. Recognizing sepsis as a global health priority - a WHO resolution. N Engl J Med. 2017;377(5):414–7. 5. Vincent JL, Moreno R, Takala J, Willatts S, De Mendonca A, Bruining H, Reinhart CK, Suter PM, Thijs LG. The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. On behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine. Intensive Care Med. 1996;22(7):707–10.