Piloting Rasch model scoring of the National Eye Institute Visual Function Questionnaire in uveitis

Author:

Gittel Lisa,Li Jeany Q.,Dell Jennifer,Wintergerst Maximilian W. M.,Heinz Carsten,Finger Robert P.,Terheyden Jan Henrik

Abstract

Abstract Introduction The National Eye Institute Visual Function Questionnaire (NEI VFQ) is a common patient-reported outcome measure (PROM) in uveitis trials. Its psychometric properties using state-of-the-art scoring based on Rasch models, a latent trait model that improves accuracy of PROMs assessment, has not yet been investigated. Methods The study participants were recruited online from uveitis patient organizations, where individuals self-reported their uveitis diagnosis and visual acuity level. These participants then completed the NEI VFQ-25. The visual function (VF) and socioemotional (SE) subscales were psychometrically analysed in terms of item fit, targeting, internal consistency, dimensionality, and differential item functioning (DIF), using Rasch models. Criterion validity was examined based on associations between NEI VFQ person measures and recent visual acuity (VA) levels. Results Ninety-nine participants recruited online from uveitis patient organizations (68 women, 31 men; mean age 50 ± 15 years; 46.5% self-reported receiving systematic therapy for uveitis, 0.6% NEI VFQ-25 missing data) were included. The mean difficulty of items was lower than the average person ability. None of the items demonstrated misfit to an extent that would induce noise into the measurement. The consistency metrics person reliability and person separation index of the subscales were 0.85 and 2.34 (NEI VFQ-VF), 0.86 and 2.52 (NEI VFQ-SE), respectively. There was no evidence of multidimensionality and none of the items showed DIF by gender. The differences between item and person measures were 1.44 (NEI VFQ-VF) and 1.03 (NEI VFQ-SE). NEI VFQ-25 person measures were significantly lower in participants with visual impairment (all p values ≤ 0.007). Conclusion Rasch model-based scoring of the re-engineered NEI VFQ-25 demonstrates acceptable internal consistency, item fit and construct validity for assessing two key domains of quality of life in individuals self-reporting uveitis. The PROM was targeted at a higher level of difficulty than present in our heterogeneous sample.

Funder

Deutsche Ophthalmologische Gesellschaft

Universitätsklinikum Bonn

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3