Precision of computed tomography and cartilage-reproducing image reconstruction method in generating digital model for potential use in 3D printing of patient-specific radial head prosthesis: a human cadaver study

Author:

Luenam SuriyaORCID,Bantuchai Theeraset,Kosiyatrakul Arkaphat,Chanpoo Malee,Phakdeewisetkul Kantapat,Puncreobutr Chedtha

Abstract

Abstract Background A prosthetic replacement is a standard treatment for an irreparable radial head fracture; however, the surface mismatch of the commercially available designs is concerned for the long-term cartilage wear. The patient-specific implant created from 3D printing technology could be favorable in replicating the normal anatomy and possibly reduce such sequela. Our study aimed to assess the precision of the computed tomography (CT) and cartilage-reproducing image reconstruction method (CIRM) in generating digital models for potentially use in manufacturing the patient-specific prosthesis from 3D printing. Methods Eight intact  elbows (3 right and 5 left) from 7 formalin-embalmed cadavers (4 males and 3 females) with mean age of 83 years (range, 79–94 years) were used for this study. Computerized 3D models were generated from CT, and CIRM. The cartilage-reproducing image reconstruction method has compensated the cartilage profile based on the distance between the subchondral surfaces of the radial head and surrounding bones in CT images. The models of actual radial head geometry used as the gold standard was generated from CT arthrography (CTA). All models of each specimen were matched by registering the surface area of radial neck along with the tuberosity. The difference of head diameter, head thickness, and articular disc depth among three models was evaluated and analyzed by Friedman ANOVA and multiple comparison test using Bonferroni method for statistical correction. A p-value of less than 0.01 was considered statistically  significant. The difference of overall 3D geometry was measured with the root mean square of adjacent point pairs. Results The analysis displayed the difference of diameter, thickness, and disc depth across the models (p< 0.01). Pairwise comparisons revealed statistically significant difference of all parameters between CTA models and CT models (p< 0.01) whereas no difference was found between CTA models and CIRM models. The mean difference of overall 3D geometry between CTA models and CT models was 0.51±0.24 mm, and between CTA models and CIRM models was 0.24±0.10 mm. Conclusions CIRM demonstrated encouraging results in reestablish the normal anatomy and could be potentially used in production process of 3D printed patient-specific radial head prosthesis.

Publisher

Springer Science and Business Media LLC

Subject

Computer Science Applications,Radiology Nuclear Medicine and imaging,Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3