Stereolithography (STL) measurement rubric for the evaluation of craniomaxillofacial STLs

Author:

Muller Henra,Fossey Annabel

Abstract

Abstract Background Facial deformities often demand reconstructive surgery and the placement of three-dimensional (3D) printed craniomaxillofacial prostheses. Prostheses manufacturing requires patients’ computed tomography (CT) images. Poor quality images result in incorrectly sized prostheses, necessitating repeat imaging and refitting. The Centre for Rapid Prototyping and Manufacturing (CRPM) produces most facial prostheses in South Africa but does not have a prescribed optimised CT protocol. Therefore, this study was undertaken. Methods A collection of CRPM STLs used in the design and manufacturing of craniomaxillofacial prostheses is available. The image quality of stereolithography (STL) files of CRPM CT scans was evaluated to determine what constitutes good image quality. This collection was scrutinised for inclusion in the image quality evaluation. After scrutiny, 35 STLs of individuals ≥15 years of age were selected and included metadata attached to the DICOM file. Furthermore, only STLs created without manipulation by the same designer were included in the collection. Before the qualitative evaluation of the STLs, eight different critical anatomical reference points (CARPs) were identified with the assistance of an expert team. A visual acuity rating scale of three categories was devised for each CARP, where 1 was allocated to poor visual acuity, 2 to partial, and 3 to good visual acuity. Similarly, rating scales were devised for the presence of concentric rings and the overall impression score awarded by the two designers involved in the design and manufacturing of the prostheses. This stereolithography measurement rubric (SMR) was then applied to the 35 STLs by a team of three experts, including the two designers, during a structured evaluation session. The scores were used to calculate summary and inferential statistics. Results Scores grouped around the central rating of partial visual acuity. The three evaluators’ mean total CARP scores ranged from 13.1 to 14.4 (maximum possible score 24), while the mean total CARP + ring scores ranged from 15.8 to 17.1 (maximum possible score 27). No significant differences were detected between the evaluators’ scores. Conclusion This SMR appears to be the first of its kind. This image quality assessment of STLs provides the groundwork for finer CT image quality evaluation to formulate a CT imaging protocol for the CRPM to design and manufacture accurate internal cranial prostheses.

Publisher

Springer Science and Business Media LLC

Subject

Computer Science Applications,Radiology, Nuclear Medicine and imaging,Biomedical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3