Fluoroscopically calibrated 3D-printed patient-specific instruments improve the accuracy of osteotomy during bone tumor resection adjacent to joints

Author:

Wang Chen,Huang Siyi,Yu Yue,Liang Haijie,Wang Ruifeng,Tang Xiaodong,Ji Tao

Abstract

Abstract Background Inadequate surface matching, variation in the guide design, and soft tissue on the skeletal surface may make it difficult to accurately place the 3D-printed patient-specific instrument (PSI) exactly to the designated site, leading to decreased accuracy, or even errors. Consequently, we developed a novel 3D-printed PSI with fluoroscopy-guided positioning markers to enhance the accuracy of osteotomies in joint-preserving surgery. The current study was to compare whether the fluoroscopically calibrated PSI (FCPSI) can achieve better accuracy compared with freehand resection and conventional PSI (CPSI) resection. Methods Simulated joint-preserving surgery was conducted using nine synthetic left knee bone models. Osteotomies adjacent to the knee joint were designed to evaluate the accuracy at the epiphysis side. The experiment was divided into three groups: free-hand, conventional PSI (CPSI), and fluoroscopically Calibrated PSI (FCPSI). Post-resection CT scans were quantitatively analyzed. Analysis of variance (ANOVA) was used. Result FCPSI improved the resection accuracy significantly. The mean location accuracy is 2.66 mm for FCPSI compared to 6.36 mm (P < 0.001) for freehand resection and 4.58 mm (P = 0.012) for CPSI. The mean average distance is 1.27 mm compared to 2.99 mm (p < 0.001) and 2.11 mm (p = 0.049). The mean absolute angle is 2.16° compared to 8.50° (p < 0.001) and 5.54° (p = 0.021). The mean depth angle is 1.41° compared to 8.10° (p < 0.001) and 5.32° (p = 0.012). However, there were no significant differences in the front angle compared to the freehand resection group (P = 0.055) and CPSI (P = 0.599) group. The location accuracy observed with FCPSI was maintained at 4 mm, while CPSI and freehand resection exhibited a maximum deviation of 8 mm. Conclusion The fluoroscopically calibrated 3D-printed patient-specific instruments improve the accuracy of osteotomy during bone tumor resection adjacent to joint joints compared to conventional PSI and freehand resection. In conclusion, this novel 3D-printed PSI offers significant accuracy improvement in joint preserving surgery with a minimal increase in time and design costs.

Funder

Peking University People’s Hospital Scientific Research Development Funds

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3