Abstract
Abstract
Purpose
This systematic review aimed to investigate the accuracy of intraoral scan (IOS) impressions of implant-supported restorations in in vivo studies.
Methods
A systematic electronic search and review of studies on the accuracy of IOS implant impressions were conducted to analyze the peer-reviewed literature published between 1989 and August 2023. The bias analysis was performed by two reviewers. Data on the study characteristics, accuracy outcomes, and related variables were extracted. A meta-analysis of randomized control trials was performed to investigate the impact of IOS on peri-implant crestal bone loss and the time involved in the impression procedure.
Results
Ten in vivo studies were included in this systematic review for final analysis. Six studies investigated the trueness of IOS impressions, but did not reach the same conclusions. One study assessed the precision of IOS impressions for a single implant. Four clinical studies examined the accuracy of IOS implant impressions with a follow-up of 1–2 years. In full arches, IOS impression procedure needed significantly less time than conventional one (mean difference for procedure time was 8.59 min [6.78, 10.40 min], P < 0.001), prosthetic survival rate was 100%, and marginal bone levels of all participants could be stably maintained (mean difference in marginal bone loss at 12 months was 0.03 mm [-0.08, 0.14 mm], P = 0.55).
Conclusions
The accuracy of IOS impressions of implant-supported restorations varied greatly depending on the scanning strategy. The trueness and precision of IOS in the partial and complete arches remain unclear and require further assessment. Based on follow-up clinical studies, IOS impressions were accurate in clinical practice. However, these results should be interpreted with caution, as some evidences are obtained from the same research group.
Funder
Medical Research Project of Xuhui District, Shanghai
Publisher
Springer Science and Business Media LLC
Reference55 articles.
1. Buzayan MM, Yunus NB. Passive fit in screw retained multi-unit implant prosthesis understanding and achieving: a review of the literature. J Indian Prosthodont Soc. 2014;14(1):16–23.
2. Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: current status. Implant Dent. 2001;10(2):85–92.
3. Michaels GC, Carr AB, Larsen PE. Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997;83(2):198–205.
4. Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol. 2017;10(Suppl 1):121–38.
5. Flügge T, van der Meer WJ, Gonzalez BG, Vach K, Wismeijer D, Wang P. The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):374–92.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献