Author:
Zhang Wen,Wang Jiang-Ling,Fu Shuang,Zhou Jia-Ming,Zhu Ye-Jing,Cai Shu-Nv,Fang Jun,Xie Kang-Jie,Chen Xin-Zhong
Abstract
Abstract
Background
Patients with obstructive sleep apnoea (OSA), male sex, obesity, older age or hypertension are prone to hypoxemia during flexible bronchoscopy. This study investigated whether using a high-flow nasal cannula (HFNC) could reduce the incidence of oxygen desaturation during bronchoscopy under deep sedation in patients at risk of hypoxemia.
Methods
A total of 176 patients at risk of hypoxemia who underwent flexible bronchoscopy under deep sedation were randomly assigned to two groups: the HFNC group (humidified oxygen was supplied via a high-flow nasal cannula at a rate of 60 L/min and a concentration of 100%, n = 87) and the facemask group (oxygen was supplied via a tight-fitting facemask at a rate of 6 L/min and a concentration of 100%, n = 89).
Results
Oxygen desaturation occurred in 4 (4.6%) patients in the HFNC group and 26 (29.2%) patients in the facemask group (P < 0.001). The facemask group required more jaw thrust manoeuvres than the HFNC group (43[48.3%] vs. 5[5.7%], P < 0.001). 8 patients (9.0%) in the facemask group and none in the HFNC group required bag-mask ventilation (P = 0.012).
Conclusion
The use of an HFNC can reduce the incidence of oxygen desaturation and the requirement for airway intervention in patients at risk of hypoxemia during flexible bronchoscopy under deep sedation.
Trial registration:
www.chiCTR.org.cn Identifier: ChiCTR2100044105. Registered 11/03/2021.
Funder
the Basic Public Welfare Research Project in Zhejiang Province
Publisher
Springer Science and Business Media LLC
Subject
Pulmonary and Respiratory Medicine
Cited by
6 articles.