Using intra-breath oscillometry in obesity hypoventilation syndrome to detect tidal expiratory flow limitation: a potential marker to optimize CPAP therapy

Author:

Baglyas Szabolcs,Valkó Luca,Móró Vivien,Podmaniczky Eszter,Czövek Dorottya,Makan Gergely,Gingl Zoltán,Gál János,Hantos Zoltán,Lorx András

Abstract

Abstract Background Continuous positive airway pressure (CPAP) therapy has profound effects in obesity hypoventilation syndrome (OHS). Current therapy initiation focuses on upper airway patency rather than the assessment of altered respiratory mechanics due to increased extrapulmonary mechanical load. Methods We aimed to examine the viability of intra-breath oscillometry in optimizing CPAP therapy for OHS. We performed intra-breath oscillometry at 10 Hz in the sitting and supine positions, followed by measurements at increasing CPAP levels (none-5-10-15-20 cmH2O) in awake OHS patients. We plotted intra-breath resistance and reactance (Xrs) values against flow (V’) and volume (V) to identify tidal expiratory flow limitation (tEFL). Results Thirty-five patients (65.7% male) completed the study. We found a characteristic looping of the Xrs vs V’ plot in all patients in the supine position revealing tEFL: Xrs fell with decreasing flow at end-expiration. Intra-breath variables representing expiratory decrease of Xrs became more negative in the supine position [end-expiratory Xrs (mean ± SD): -1.9 ± 1.8 cmH2O·s·L− 1 sitting vs. -4.2 ± 2.2 cmH2O·s·L− 1 supine; difference between end-expiratory and end-inspiratory Xrs: -1.3 ± 1.7 cmH2O·s·L− 1 sitting vs. -3.6 ± 2.0 cmH2O·s·L− 1 supine, p < 0.001]. Increasing CPAP altered expiratory Xrs values and loop areas, suggesting diminished tEFL (p < 0.001). ‘Optimal CPAP’ value (able to cease tEFL) was 14.8 ± 4.1 cmH2O in our cohort, close to the long-term support average of 13.01(± 2.97) cmH2O but not correlated. We found no correlation between forced spirometry values, patient characteristics, apnea-hypopnea index and intra-breath oscillometry variables. Conclusions tEFL, worsened by the supine position, can be diminished by stepwise CPAP application in most patients. Intra-breath oscillometry is a viable method to detect tEFL during CPAP initiation in OHS patients and tEFL is a possible target for optimizing therapy in OHS patients.

Funder

Hungarian Scientific Research Fund

János Bolyai Research Scholarship of the Hungarian Academy of Sciences

European Respiratory Society Clinical Research Collaboration Award

Publisher

Springer Science and Business Media LLC

Subject

Pulmonary and Respiratory Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3