Abstract
Abstract
Background
The expiratory time constant (RCEXP), which is defined as the product of airway resistance and lung compliance, enable us to assess the mechanical properties of the respiratory system in mechanically ventilated patients. Although RCEXP could also be applied to spontaneously breathing patients, little is known about RCEXP calculated from the maximal expiratory flow-volume (MEFV) curve. The aim of our study was to determine the reference value for RCEXP, as well as to investigate the association between RCEXP and other respiratory function parameters, including the forced expiratory volume in 1 s (FEV1)/ forced vital capacity (FVC) ratio, maximal mid-expiratory flow rate (MMF), maximal expiratory flow at 50 and 25% of FVC (MEF50 and MEF25, respectively), ratio of MEF50 to MEF25 (MEF50/MEF25).
Methods
Spirometric parameters were extracted from the records of patients aged 15 years or older who underwent pulmonary function testing as a routine preoperative examination before non-cardiac surgery at the University of Tokyo Hospital. RCEXP was calculated in each patient from the slope of the descending limb of the MEFV curve using two points corresponding to MEF50 and MEF25. Airway obstruction was defined as an FEV1/FVC and FEV1 below the statistically lower limit of normal.
Results
We retrospectively analyzed 777 spirometry records, and 62 patients were deemed to have airway obstruction according to Japanese spirometric reference values. The cut-off value for RCEXP was 0.601 s with an area under the receiver operating characteristic curve of 0.934 (95% confidence interval = 0.898–0.970). RCEXP was strongly associated with FEV1/FVC, and was moderately associated with MMF and MEF50. However, RCEXP was less associated with MEF25 and MEF50/MEF25.
Conclusions
Our findings suggest that an RCEXP of longer than approximately 0.6 s can be linked to the presence of airway obstruction. Application of the concept of RCEXP to spontaneously breathing subjects was feasible, using our simple calculation method.
Publisher
Springer Science and Business Media LLC
Subject
Pulmonary and Respiratory Medicine
Reference33 articles.
1. Brunner JX, Laubscher TP, Banner MJ, Iotti G, Braschi A. Simple method to measure total expiratory time constant based on the passive expiratory flow-volume curve. Crit Care Med. 1995;17:1117–22.
2. Mead J. Analysis of the configuration of maximum expiratory flow-volume curves. J Appl Physiol Respir Environ Exerc Physiol. 1978;44:156–65.
3. Lourens MS, van den Berg B, Aerts JG, Verbraak AF, Hoogsteden HC, Bogaard JM. Expiratory time constants in mechanically ventilated patients with and without COPD. Intensive Care Med. 2000;26(11):1612–8.
4. Arnal JM, Garnero A, Saoli M, Chatburn RL. Parameters for simulation of adult subjects during mechanical ventilation. Respir Care. 2018;63(2):158–68.
5. Arora VK, Raghu S. Flow volume curves: clinical significance. Lung India. 1996;14:169–71.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献