Factors influencing nasal airway pressure and comfort in high-flow nasal cannula oxygen therapy: a volunteer study

Author:

Zhao Enqi,Zhou Yilong,He Chunwei,Ma Dedong

Abstract

Abstract Background High-flow nasal cannula (HFNC) oxygen therapy is essentially a constant-flow, noninvasive respiratory support system similar to a noninvasive ventilator operating in constant-flow mode. The clinical outcome of HFNC oxygen therapy is strongly associated with the pressure generated by high-flow gas and the patient’s comfort level. This study was performed to explore the relevant factors affecting pressure and comfort of HFNC oxygen therapy in vivo. Methods Thirty-five healthy volunteers were enrolled in the trial. They underwent placement of nasal cannulas of various inner diameters (3, 4 or 5 mm) and treatment with different HFNC devices [HFT-300 (Weishengkang Medical Technology Co., Ltd., Jiangsu China) or H-80 M (BMC Medical Co., Ltd., Beijing China)],and the nasal airway pressure and comfort were assessed. Multiple linear regression was used to determine predictors of airway pressure. Results Multiple linear regression showed that the end-expiratory pressure was associated with the flow rate, sex, height, and cannula size. The end-expiratory pressure increased by 0.6 cmH2O per 1-mm increase in cannula diameter, decreased by 0.3 cmH2O per 10-cm increase in participant height (with a 0.35 cmH2O decrease for men), and increased by 1 cmH2O when the flow rate increased by 10 L/min (R2 = 0.75, P < 0.05 for all variables in model). In addition, the pressure generated by the H-80 M device was higher than that generated by the HFT-300 device (P < 0.05). Discomfort manifested as difficulty in expiration, and its severity increased as the cannula diameter increased; however there was no significant difference in comfort between the two HFNC devices (P > 0.05). Conclusion In volunteers undergoing HFNC oxygen therapy, the nasal cannula diameter, flow rate, sex, height, and device model can affect the nasal airway pressure, and the nasal catheter diameter and flow rate can affect comfort. These factors should be given close attention in clinical practice. Trial registration ChiCTR2300068313 (date of first registration: 14 February 2023, https://www.chictr.org.cn).

Publisher

Springer Science and Business Media LLC

Subject

Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3