Criterion validity for step counting in four consumer-grade physical activity monitors among older adults with and without rollators

Author:

Larsen Rasmus TolstrupORCID,Korfitsen Christoffer Brun,Juhl Carsten Bogh,Andersen Henning Boje,Langberg Henning,Christensen Jan

Abstract

Abstract Background Few studies have investigated the measurement properties of consumer-grade physical activity monitors (PAMs) in older adults. Therefore, we investigated the criterion validity of consumer-grade PAMs in older adults and whether the measurement properties differed between older adults with and without rollators and whether worn on the hip or at the wrist. Methods Consumer-grade PAMs were eligible for inclusion in this study if they: 1) could be fastened at the hip as well as on the wrist, 2) were simple in function and design and thus easy to use for participants with minimal technical skills, 3) included step-counting as outcome measure and 4) were powered by a button cell battery. Participants performed self-paced walking for six minutes while two physiotherapists counted their steps with a click-counter. The average of the two counts was used as criterion. The participants wore 16 monitors, four located bilaterally on both hips and wrists. Our prior expectation was that all monitors would have at least moderate criterion validity for all participants, good criterion validity for participants walking without a rollator and poor criterion validity for participants walking with a rollator. Results Four physical activity monitors were included in this study; Misfit Shine, Nokia GO, Jawbone UP Move and Garmin Vivofit 3. A total of 103 older adults participated. Nokia GO was excluded from this study due to technical issues. Therefore, we present results on the frequency of data loss, ICC (1, 2) and percentage measurement error for Misfit Shine, Garmin Vivofit 3 and Jawbone UP Move located on four different positions. Conclusions The hip-worn PAMs did not differ significantly in terms of measurement error or criterion validity. Wrist-worn monitors cannot adequately measure number of steps in a population of older adults using rollators. The hip-worn PAMs were superior to wrist-worn PAMs among older adults with and without rollators.

Funder

Horizon 2020

Publisher

Springer Science and Business Media LLC

Subject

Geriatrics and Gerontology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3