Prevention of ventilator-associated pneumonia by noble metal coating of endotracheal tubes: a multi-center, randomized, double-blind study

Author:

Damas PierreORCID,Legrain Caroline,Lambermont Bernard,Dardenne Nadia,Guntz Julien,Kisoka Grâce,Demaret Pierre,Rousseau Anne-Françoise,Jadot Laurent,Piret Sonia,Noirot Didier,Bertrand Axelle,Donneau Anne-Françoise,Misset Benoît

Abstract

Abstract Background Ventilator-associated pneumonia (VAP) causes increased mortality, prolonged hospital stay and increased healthcare costs. Prevention of VAP in intensive care units (ICUs) is currently based on several measures, and application of noble metal coating on medical devices has been shown to inhibit the bacterial adherence of microorganisms to the surface. The objective of this study was to evaluate the potential benefit of noble metal coating of endotracheal tubes for the prevention of VAP. Methods This was a multi-center, randomized, controlled, double-blind, prospective study including ventilated patients from nine ICUs from four hospital sites in Belgium. Patients were randomly intubated with identical appearing noble metal alloy (NMA) coated (NMA-coated group) or non-coated (control group) endotracheal tubes (ETT). Primary endpoint was the incidence of VAP. Secondary endpoints were the proportion of antibiotic days during ICU stay and tracheal colonization by pathogenic bacteria. Results In total, 323 patients were enrolled, 168 in the NMA-coated group and 155 in the control group. During ventilation, VAP occurred in 11 patients (6.5%) in the NMA-coated group and in 18 patients (11.6%) in the control group (p  = 0.11). A higher delay in VAP occurrence was observed in the NMA-coated group compared with the control group by Cox proportional hazards regression analysis (HR 0.41, 95% CI 0.19–0.88, p  = 0.02). The number of antibiotic days was 58.8% of the 1,928 ICU days in the NMA-coated group and 65.4% of the 1774 ICU days in the control group (p  = 0.06). Regarding tracheal colonization, bacteria occurred in 38 of 126 patients in the NMA-coated group (30.2%) and in 37 of 109 patients in the control group (33.9%) (p  = 0.57). Conclusions This study provides preliminary evidence to support the benefit of noble metal coating in the prevention of VAP. A confirmatory study in a larger population would be valuable. Trial registration: Clinical trial number: NCT04242706 (http://www.clinicaltrials.gov)

Funder

Bactiguard AB

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3