Duration of hemodynamic effects of crystalloids in patients with circulatory shock after initial resuscitation

Author:

Nunes Thieme Souza Oliveira,Ladeira Renata Teixeira,Bafi Antônio Tonete,de Azevedo Luciano Cesar Pontes,Machado Flavia Ribeiro,Freitas Flávio Geraldo Rezende

Abstract

Abstract Background In the later stages of circulatory shock, monitoring should help to avoid fluid overload. In this setting, volume expansion is ideally indicated only for patients in whom the cardiac index (CI) is expected to increase. Crystalloids are usually the choice for fluid replacement. As previous studies evaluating the hemodynamic effect of crystalloids have not distinguished responders from non-responders, the present study was designed to evaluate the duration of the hemodynamic effects of crystalloids according to the fluid responsiveness status. Methods This is a prospective observational study conducted after the initial resuscitation phase of circulatory shock (>6 h vasopressor use). Critically ill, sedated adult patients monitored with a pulmonary artery catheter who received a fluid challenge with crystalloids (500 mL infused over 30 min) were included. Hemodynamic variables were measured at baseline (T0) and at 30 min (T1), 60 min (T2), and 90 min (T3) after a fluid bolus, totaling 90 min of observation. The patients were analyzed according to their fluid responsiveness status (responders with CI increase >15% and non-responders ≤15% at T1). The data were analyzed by repeated measures of analysis of variance. Results Twenty patients were included, 14 of whom had septic shock. Overall, volume expansion significantly increased the CI: 3.03 ± 0.64 L/min/m2 to 3.58 ± 0.66 L/min/m2 (p < 0.05). From this period, there was a progressive decrease: 3.23 ± 0.65 L/min/m2 (p < 0.05, T2 versus T1) and 3.12 ± 0.64 L/min/m2 (p < 0.05, period T3 versus T1). Similar behavior was observed in responders (13 patients), 2.84 ± 0.61 L/min/m2 to 3.57 ± 0.65 L/min/m2 (p < 0.05) with volume expansion, followed by a decrease, 3.19 ± 0.69 L/min/m2 (p < 0.05, T2 versus T1) and 3.06 ± 0.70 L/min/m2 (p < 0.05, T3 versus T1). Blood pressure and cardiac filling pressures also decreased significantly after T1 with similar findings in both responders and non-responders. Conclusions The results suggest that volume expansion with crystalloids in patients with circulatory shock after the initial resuscitation has limited success, even in responders.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 84 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3