Preoxygenation with standard facemask combining apnoeic oxygenation using high flow nasal cannula versuss standard facemask alone in patients with and without obesity: the OPTIMASK international study

Author:

Jaber Samir,De Jong Audrey,Schaefer Maximilian S.,Zhang Jiaqiang,Ma Xiaowen,Hao Xinrui,Zhou Shujing,Lv Shang,Banner-Goodspeed Valerie,Niu Xiuhua,Sfara Thomas,Talmor Daniel

Abstract

Abstract Background Combining oxygen facemask with apnoeic oxygenation using high-flow-nasal-oxygen (HFNO) for preoxygenation in the operating room has not been studied against standard oxygen facemask alone. We hypothesized that facemask-alone would be associated with lower levels of lowest end-tidal oxygen (EtO2) within 2 min after intubation in comparison with facemask combined with HFNO. Methods In an international prospective before–after multicentre study, we included adult patients intubated in the operating room from September 2022 to December 2022. In the before period, preoxygenation was performed with facemask-alone, which was removed during laryngoscopy. In the after period, facemask combined with HFNO was used for preoxygenation and HFNO for apnoeic oxygenation during laryngoscopy. HFNO was maintained throughout intubation. The primary outcome was the lowest EtO2 within 2 min after intubation. The secondary outcome was SpO2 ≤ 95% within 2 min after intubation. Subgroup analyses were performed in patients without and with obesity. This study was registered 10 August 2022 with ClinicalTrials.gov, number NCT05495841. Results A total of 450 intubations were evaluated, 233 with facemask-alone and 217 with facemask combined with HFNO. In all patients, the lowest EtO2 within 2 min after intubation was significantly lower with facemask-alone than with facemask combined with HFNO, 89 (85–92)% vs 91 (88–93)%, respectively (mean difference − 2.20(− 3.21 to − 1.18), p < 0.001). In patients with obesity, similar results were found [87(82–91)% vs 90(88–92)%, p = 0.004]; as in patients without obesity [90(86–92)% vs 91(89–93)%, p = 0.001)]. SpO2 ≤ 95% was more frequent with facemask-alone (14/232, 6%) than with facemask combined with HFNO (2/215, 1%, p = 0.004). No severe adverse events were recorded. Conclusions Combining facemask with HFNO for preoxygenation and apnoeic oxygenation was associated with increased levels of lowest EtO2 within 2 min after intubation and less desaturation.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3