Castro Ricardo,Kattan Eduardo,Ferri Giorgio,Pairumani Ronald,Valenzuela Emilio Daniel,Alegría Leyla,Oviedo Vanessa,Pavez Nicolás,Soto Dagoberto,Vera Magdalena,Santis César,Astudillo Brusela,Cid María Alicia,Bravo Sebastian,Ospina-Tascón Gustavo,Bakker Jan,Hernández GlennORCID

Abstract

Abstract Background Persistent hyperlactatemia has been considered as a signal of tissue hypoperfusion in septic shock patients, but multiple non-hypoperfusion-related pathogenic mechanisms could be involved. Therefore, pursuing lactate normalization may lead to the risk of fluid overload. Peripheral perfusion, assessed by the capillary refill time (CRT), could be an effective alternative resuscitation target as recently demonstrated by the ANDROMEDA-SHOCK trial. We designed the present randomized controlled trial to address the impact of a CRT-targeted (CRT-T) vs. a lactate-targeted (LAC-T) fluid resuscitation strategy on fluid balances within 24 h of septic shock diagnosis. In addition, we compared the effects of both strategies on organ dysfunction, regional and microcirculatory flow, and tissue hypoxia surrogates. Results Forty-two fluid-responsive septic shock patients were randomized into CRT-T or LAC-T groups. Fluids were administered until target achievement during the 6 h intervention period, or until safety criteria were met. CRT-T was aimed at CRT normalization (≤ 3 s), whereas in LAC-T the goal was lactate normalization (≤ 2 mmol/L) or a 20% decrease every 2 h. Multimodal perfusion monitoring included sublingual microcirculatory assessment; plasma-disappearance rate of indocyanine green; muscle oxygen saturation; central venous-arterial pCO2 gradient/ arterial-venous O2 content difference ratio; and lactate/pyruvate ratio. There was no difference between CRT-T vs. LAC-T in 6 h-fluid boluses (875 [375–2625] vs. 1500 [1000–2000], p = 0.3), or balances (982[249–2833] vs. 15,800 [740–6587, p = 0.2]). CRT-T was associated with a higher achievement of the predefined perfusion target (62 vs. 24, p = 0.03). No significant differences in perfusion-related variables or hypoxia surrogates were observed. Conclusions CRT-targeted fluid resuscitation was not superior to a lactate-targeted one on fluid administration or balances. However, it was associated with comparable effects on regional and microcirculatory flow parameters and hypoxia surrogates, and a faster achievement of the predefined resuscitation target. Our data suggest that stopping fluids in patients with CRT ≤ 3 s appears as safe in terms of tissue perfusion. Clinical Trials: ClinicalTrials.gov Identifier: NCT03762005 (Retrospectively registered on December 3rd 2018)

Funder

FONDECYT Chile

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3