Comparison of survival for super high-flux hemodialysis (SHF-HD) with high albumin leakage versus online hemodiafiltration or SHF-HD with low albumin leakage: the SUPERB study

Author:

Okada Kazuyoshi,Tashiro Manabu,Michiwaki Hiroyuki,Inoue Tomoko,Shima Hisato,Minakuchi Jun,Kawashima Shu

Abstract

Abstract Background Survival is equivalent between super high-flux hemodialysis (SHF-HD) and online hemodiafiltration (OHDF) with similar albumin leakage. According to the 2013 Japanese dialyzer performance classification, survival on HD is optimal when a type II dialyzer (β2-microglobulin clearance ≥ 70 mL/min) is used. Here, we investigated whether survival could be improved by SHF-HD using a type II-b dialyzer (sieving coefficient for albumin ≥ 0.03) with high albumin leakage compared with OHDF or SHF-HD using a type II-a dialyzer (sieving coefficient for albumin < 0.03) with low albumin leakage. Methods This 3-year retrospective observational propensity score-matched study included 738 patients receiving SHF-HD (n = 310) or OHDF (n = 428) with a type II dialyzer at our institution between April 1 and July 1, 2017. Three-year all-cause mortality was compared for SHF-HD with high estimated albumin leakage (EAL) versus OHDF and SHF-HD with low EAL. Kaplan–Meier survival curves were compared using the log-rank test and hazard ratios were calculated by Cox regression analysis. Results Mortality in SHF-HD with high EAL was significantly lower than OHDF with low EAL (each n = 52 after matching; P = 0.007, log-rank test). All the dialyzers used a polyethersulfone (PES) membrane, whereas none of the hemodiafilters had a PES membrane. In SHF-HD, mortality was significantly lower when EAL was ≥ 3.0 g/session than when EAL was < 3.0 g/session (each n = 115 after matching, P = 0.004, log-rank test) and when the dialyzer used was type II-b rather than type II-a (each n = 133 after matching, P = 0.001, log-rank test). Conclusions These findings suggest that survival is better on SHF-HD using a type II-b dialyzer with high albumin leakage than on OHDF with low albumin leakage or SHF-HD using a type II-a dialyzers. The PES used in the type II-b dialyzer may also have a beneficial effect on survival.

Publisher

Springer Science and Business Media LLC

Subject

Transplantation,Urology,Nephrology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3