Abstract
AbstractBackgroundCatheter-related infection of peritoneal dialysis (PD) is one of the serious factors of peritonitis. However, an antibacterial PD catheter has not been commercially available in Japan yet. From an infection control viewpoint, it is necessary to develop an antibacterial coating material for catheters with a long-term effectiveness.MethodsFluorinated hydroxyapatite (F-HAp) nanoparticles were prepared by a wet chemical process. F-HAps with different F substitution contents were prepared by adjusting the feed ratio of F ions versus sites of OH groups in HAp structures. The characterization and evaluation of F-HAps were conducted using several analytical equipment and an antibacterial powder assay.ResultsThe F-HAp nanoparticles possessed highly crystalline and dispersibility. The F-HAps were named as F(30)-HAp, F(50)-HAp, and F(100)-HAp and were 24, 52, and 84% of the actual F substitution content, respectively. The nanomaterials showed acidic resistance, i.e., chemical stability, compared to normal HAp. In an antibacterial assay of F(100)-HAp with 50 mg in 0.2 mL of NaCl aqueous solution, four types of causative bacteria of catheter-related infections,Pseudomonas aeruginosa,Staphylococcus aureus,Enterobacter aerogenes, andKlebsiella pneumoniaewere used. The antibacterial activities of F(100)-HAp showed 50–60% against the microorganisms. F ions were gradually released and finally plateaued at 24 weeks.ConclusionsThe retention possibility of the antibacterial effect of F(100)-HAp potentially lasted for 24 weeks based on the F ions release behavior. It is expected that the antibacterial performance can be improved by the precise control of material engineering technology, although the duration of the effect has not yet been satisfactory for a PD catheter.
Funder
JSPS Grant-in-Aid for Scientific Research (C)
Publisher
Springer Science and Business Media LLC
Subject
Transplantation,Urology,Nephrology
Reference25 articles.
1. Li PK, Szeto CC, Piraino B, Arteaga J, Fan S, Figueiredo AE, Fish DN, Goffin E, Kim Y, Salzer W, Struijk DG, Teitelbaum I, Johnson DW. ISPD Peritonitis recommendations: 2016 update on prevention and treatment. Perit Dial Int. 2016;36:481–508.
2. Szeto CC, Li PK, Johnson DW, Bernardini J, Dong J, Figueiredo AE, Ito Y, Kazancioglu R, Moraes T, Esch SV, Brown EA. ISPD Catheter-related infection recommendations: 2017 update. Perit Dial Int. 2017;37:141–54.
3. van Diepen AT, Tomlinson GA, Jassal SV. The association between exit site infection and subsequent peritonitis among peritoneal dialysis patients. Clin J Am Soc Nephrol. 2012;7:1266–71.
4. Crabtree JH, Burchette RJ, Siddiqi RA, Huen IT, Hadnott LL, Fishman A. The efficacy of silver-ion implanted catheters in reducing peritoneal dialysis-related infections. Perit Dial Int. 2003;23:368–74.
5. Tobin EJ, Bambauer R. Silver coating of dialysis catheters to reduce bacterial colonization and infection. Ther Apher Dial. 2003;7:504–9.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献