Author:
Qi Yanchao,Chen Zhiyan,Guo Bingyan,Liu Zhe,Wang Lijie,Liu Suyun,Xue Lixiang,Ma Meifang,Yin Yajuan,Li Yongjun,Liu Gang
Abstract
Abstract
Background
Diabetic cardiomyopathy results in cardiac structural and functional abnormalities. Previous studies have demonstrated that inhibiting the RhoA/ROCK signalling pathway increases the injury resistance of cardiomyocytes. The early detection of cardiac structural and functional alterations may facilitate an improved understanding of the pathophysiologic progress and guide therapy. This study aimed to identify the optimal diagnostic measures for the subtle early alterations of cardiac dysfunction in type 2 diabetes mellitus (T2DM) rats.
Methods
Twenty-four rat models were divided into four groups and received treatments for 4 weeks: the CON group (control rats), the DM group (T2DM rats), the DMF group (T2DM rats receiving fasudil) and the CONF group (control rats receiving fasudil) group. Left ventricular (LV) structure was quantified by histological staining and transmission electron microscopy. LV function and myocardial deformation were assessed by high-frequency echocardiography.
Results
Treatment with fasudil, a ROCK inhibitor, significantly protected against diabetes-induced myocardial hypertrophy, fibrosis and mitochondrial dysfunction. Impaired LV performance was found in T2DM rats, as evidenced by significant reductions in the ejection fraction (EF), fractional shortening (FS) and the mitral valve (MV) E/A ratio (which decreased 26%, 34% and 20%, respectively). Fasudil failed to improve the conventional ultrasonic parameters in T2DM rats, but the myocardial deformation measured by speckle-tracking echocardiography (STE) were significantly improved (global circumferential strain, GCS: P = 0.003; GCS rate, GCSR: P = 0.021). When receiver operating characteristic (ROC) curves were used in combination with linear regression analysis, STE parameters were found to be characterized by both optimal prediction of cardiac damage [AUC (95% CI): fractional area change, FAC: 0.927 (0.744, 0.993); GCS: 0.819 (0.610, 0.945); GCSR: 0.899 (0.707, 0.984)] and stronger correlations with cardiac fibrosis (FAC: r = -0.825; GCS: r = 0.772; GCSR: r = 0.829) than conventional parameters.
Conclusion
The results suggest that STE parameters are more sensitive and specific than conventional parameters in predicting the subtle cardiac functional changes that occur in the early stage, providing new insight into the management of diabetic cardiomyopathy.