Cardiac power output accurately reflects external cardiac work over a wide range of inotropic states in pigs

Author:

Abawi Dawud,Faragli Alessandro,Schwarzl Michael,Manninger Martin,Zweiker David,Kresoja Karl-Patrik,Verderber Jochen,Zirngast Birgit,Maechler Heinrich,Steendijk Paul,Pieske Burkert,Post Heiner,Alogna AlessioORCID

Abstract

Abstract Background Cardiac power output (CPO), derived from the product of cardiac output and mean aortic pressure, is an important yet underexploited parameter for hemodynamic monitoring of critically ill patients in the intensive-care unit (ICU). The conductance catheter-derived pressure-volume loop area reflects left ventricular stroke work (LV SW). Dividing LV SW by time, a measure of LV SW min− 1 is obtained sharing the same unit as CPO (W). We aimed to validate CPO as a marker of LV SW min− 1 under various inotropic states. Methods We retrospectively analysed data obtained from experimental studies of the hemodynamic impact of mild hypothermia and hyperthermia on acute heart failure. Fifty-nine anaesthetized and mechanically ventilated closed-chest Landrace pigs (68 ± 1 kg) were instrumented with Swan-Ganz and LV pressure-volume catheters. Data were obtained at body temperatures of 33.0 °C, 38.0 °C and 40.5 °C; before and after: resuscitation, myocardial infarction, endotoxemia, sevoflurane-induced myocardial depression and beta-adrenergic stimulation. We plotted LVSW min− 1 against CPO by linear regression analysis, as well as against the following classical indices of LV function and work: LV ejection fraction (LV EF), rate-pressure product (RPP), triple product (TP), LV maximum pressure (LVPmax) and maximal rate of rise of LVP (LV dP/dtmax). Results CPO showed the best correlation with LV SW min− 1 (r2 = 0.89; p < 0.05) while LV EF did not correlate at all (r2 = 0.01; p = 0.259). Further parameters correlated moderately with LV SW min− 1 (LVPmaxr2 = 0.47, RPP r2 = 0.67; and TP r2 = 0.54). LV dP/dtmax correlated worst with LV SW min− 1 (r2 = 0.28). Conclusion CPO reflects external cardiac work over a wide range of inotropic states. These data further support the use of CPO to monitor inotropic interventions in the ICU.

Funder

H2020 European Research Council

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3