Author:
Xu Yuancheng,Hrybouski Stanislau,Paterson D. Ian,Li Zhiyang,Lan Yulong,Luo Lin,Shen Xinping,Xu Lingyu
Abstract
Abstract
Background
This study investigated accuracy and consistency of epicardial adipose tissue (EAT) quantification in non-ECG-gated chest computed tomography (CT) scans.
Methods
EAT volume was semi-automatically quantified using a standard Hounsfield unit threshold (− 190, − 30) in three independent cohorts: (1) Cohort 1 (N = 49): paired 120 kVp ECG-gated cardiac non-contrast CT (NCCT) and 120 kVp non-ECG-gated chest NCCT; (2) Cohort 2 (N = 34): paired 120 kVp cardiac NCCT and 100 kVp non-ECG-gated chest NCCT; (3) Cohort 3 (N = 32): paired non-ECG-gated chest NCCT and chest contrast-enhanced CT (CECT) datasets (including arterial phase and venous phase). Images were reconstructed with the slice thicknesses of 1.25 mm and 5 mm in the chest CT datasets, and 3 mm in the cardiac NCCT datasets.
Results
In Cohort 1, the chest NCCT-1.25 mm EAT volume was similar to the cardiac NCCT EAT volume, while chest NCCT-5 mm underestimated the EAT volume by 7.5%. In Cohort 2, 100 kVp chest NCCT-1.25 mm were 13.2% larger than 120 kVp cardiac NCCT EAT volumes. In Cohort 3, the chest arterial CECT and venous CECT dataset underestimated EAT volumes by ~ 28% and ~ 18%, relative to chest NCCT datasets. All chest CT-derived EAT volumes were similarly associated with significant coronary atherosclerosis with cardiac CT counterparts.
Conclusion
The 120 kVp non-ECG-gated chest NCCT-1.25 mm images produced EAT volumes comparable to cardiac NCCT. Chest CT EAT volumes derived from consistent imaging settings are excellent alternatives to the cardiac NCCT to investigate their association with coronary artery disease.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献