Systematic review on left atrial appendage closure with the LAmbre device in patients with non-valvular atrial fibrillation
-
Published:2020-02-12
Issue:1
Volume:20
Page:
-
ISSN:1471-2261
-
Container-title:BMC Cardiovascular Disorders
-
language:en
-
Short-container-title:BMC Cardiovasc Disord
Author:
Ali Muhammad, Rigopoulos Angelos G., Mammadov Mammad, Torky Abdelrahman, Auer Andrea, Matiakis Marios, Abate Elena, Bakogiannis Constantinos, Tzikas Stergios, Bigalke Boris, Sedding Daniel, Noutsias MichelORCID
Abstract
Abstract
Background
Percutaneous closure (LAAC) of the left atrial appendage (LAA) is an efficacious preventive procedure for patients with non-valvular atrial fibrillation (NVAF) and considerable bleeding risk. We sought to systematically review the available LAAC data on the novel occluder device LAmbre™.
Methods
For this systematic review, a search of the literature was conducted by 3 independent reviewers, reporting the safety and therapeutic success of LAAC in patients being treated with a LAmbre™. Publications reporting the safety and therapeutic success of LAAC using LAmbre™ in n > 5 patients were included.
Results
The literature search retrieved n = 10 publications, encompassing n = 403 NVAF patients treated with a LAmbre™ LAAC, with relevant data regarding safety and therapeutic success of the procedure. The mean CHA2DS2-VASc Score was 4.0 + 0.9, and the mean HAS-BLED score was 3.4 + 0.5. The implantation success was 99.7%, with a mean procedure time of 45.4 ± 18.7 min, and a fluoroscopy time of 9.6 ± 5.9 min, and a contrast agent volume of 96.7 ± 0.7 ml. The anticoagulation regimen was switched to DAPT post procedure in the majority of the patients (96.8%). Partial and full recapture were done in 45.5% and in 25.6%, respectively. Major complications were reported in 2.9%, with 0.3% mortality, 1.7% pericardial tamponade, 0.3% stroke, and 0.6% major bleeding complications; no device embolization was observed. During follow up at 6 or 12 months, major adverse cardiovascular events were reported in 3.3%: Stroke or TIA in 1.7%, thrombus formation on the device in 0.7%, and residual flow > 5 mm in 1.0%. In some publications, the favorable implantion properties of the LAmbre™ for difficult anatomies such as shallow or multilobular LAA anatomies were described.
Conclusions
This systematic review on the LAmbre™ LAA-occluder including n = 403 NVAF patients demonstrates an excellent implantion success rate, promising follow-up clinical data, and favorable properties for also challenging LAA anatomies,. While its design seems to be helpful in preventing device embolization, pericardial tamponade may not be substantially reduced by the LAmbre™ as compared with other established LAAC devices. Further larger prospective multicenter registries and randomized trials are needed to scrutinize the value of the LAmbre™ compared with established LAAC devices.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine
Reference43 articles.
1. Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, Castella M, Diener HC, Heidbuchel H, Hendriks J, Hindricks G, Manolis AS, Oldgren J, Popescu BA, Schotten U, Van Putte B, Vardas P, Group ESCSD. 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J. 2016;37(38):2893–962. 2. Reddy VY, Sievert H, Halperin J, Doshi SK, Buchbinder M, Neuzil P, Huber K, Whisenant B, Kar S, Swarup V, Gordon N, Holmes D, Committee PAS. Investigators. Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial. JAMA. 2014;312(19):1988–98. 3. Glikson M, Wolff R, Hindricks G, Mandrola J, Camm AJ, Lip GYH, Fauchier L, Betts TR, Lewalter T, Saw J, Tzikas A, Sternik L, Nietlispach F, Berti S, Sievert H, Bertog S, Meier B, Group ESCSD. EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion - an update. Europace. 2019; https://doi.org/10.1093/europace/euz258. [Epub ahead of print]. 4. Sievert H, Lesh MD, Trepels T, Omran H, Bartorelli A, Della Bella P, Nakai T, Reisman M, DiMario C, Block P, Kramer P, Fleschenberg D, Krumsdorf U, Scherer D. Percutaneous left atrial appendage transcatheter occlusion to prevent stroke in high-risk patients with atrial fibrillation: early clinical experience. Circ. 2002;105(16):1887–9. 5. Boersma LV, Schmidt B, Betts TR, Sievert H, Tamburino C, Teiger E, Pokushalov E, Kische S, Schmitz T, Stein KM, Bergmann MW. Investigators E. implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry. Eur Heart J. 2016;37(31):2465–74.