Author:
Abazid Rami M.,Pati Nilkanth,Elrayes Maged,Chandy Mark,Hassanin Magdi,Mathew Andrew,De Sabe,Bagur Rodrigo,Tzemos Nikolaos
Abstract
Abstract
Introduction
The aim of this study is to analyze the diagnostic value of global longitudinal strain (GLS) in detecting inducible myocardial ischemia in patients with chest pain undergoing treadmill contrast-enhanced stress echocardiography (SE).
Methods
We retrospectively enrolled all patients who underwent invasive coronary angiography after treadmill contrast-enhanced SE. Rest and peak-stress myocardial GLS, segmental LS, and LS of 4-chamber (CH), 2-CH, and 3-CH views were reported. Luminal stenosis of more than 70% or fractional flow reserve (FFR) of < 0.8 was considered significant.
Results
In total 33 patients were included in the final analysis, among whom sixteen patients (48.4%) had significant coronary artery stenosis. Averaged GLS, 3-CH, and 4-CH LS were significantly lower in patients with critical coronary artery stenosis compared to those without significant stenosis (-17.1 ± 7.1 vs. -24.2 ± 7.2, p = 0.041), (-18.2 ± 8.9 vs. -24.6 ± 8.2, p = 0.045) and (-14.8 ± 6.2 vs. -22.8 ± 7.8, p = 0.009), respectively. Receiver operating characteristic (ROC) analysis of ischemic and non-ischemic segments demonstrated that a cut-off value of -20% of stress LS had 71% sensitivity and 60% specificity for ruling out inducible myocardial ischemia (Area under the curve was AUC = 0.72, P < 0.0001).
Conclusion
Myocardial LS measured with treadmill contrast-enhanced stress echocardiography demonstrates potential value in identifying patients with inducible myocardial ischemia.
Publisher
Springer Science and Business Media LLC