Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?

Author:

Kim Myung-Sun,Ahn Yeong-Seub,Lee Sun-Ho,Jeong Hyeon Jang,Kim Young Kyu,Oh Joo Han

Abstract

Abstract Background Anatomical total shoulder arthroplasty (aTSA) has been used to manage degenerative diseases such as primary osteoarthritis. An increase in the use of this procedure has led to several developments in humeral and glenoid components to improve patient outcomes. This study aimed to compare clinical and radiological outcomes of the newly-introduced convertible metal-backed glenoid components with cemented polyethylene glenoid components in aTSA, and to determine whether the new component would be comparable to a conventional one for reducing the burden of future revision or conversion surgeries. Methods Medical records of fifty patients who underwent aTSA with at least two years of follow-up were retrospectively reviewed. Eighteen patients received convertible metal-backed glenoid components with vitamin E1-coated liner (MB group), while thirty-two patients received conventional cemented polyethylene glenoid components (PE group). Pre- and postoperative clinical and radiological outcomes (acromion-greater tuberosity angle [AGA] and humeral lateral offset [LO]) at final follow-up were assessed. Radiolucent lines (RLLs) and loosening around the humeral and glenoid components were also evaluated. Results Clinical outcomes improved after surgery in both groups (all p < 0.001). The arc of rotation measured by AGA improved postoperatively in both groups (all p < 0.001), and AGA and LO were not different according to the type of glenoid components (all p > 0.05). Overall complication rates including RLLs of PE and MB groups were 43.8% (14/32) and 16.7% (3/18), respectively (p = 0.031). Although the PE group had more RLLs than did the MB group (p < 0.05), related symptoms and/or glenoid implant loosening were not observed in both groups. Subscapularis failure occurred in two patients in the PE group and in one in the MB group. Conclusion The convertible metal-backed glenoid implant with vitamin E1-coated liner may be a good alternative for considering the potential for an easier conversion to reverse total shoulder arthroplasty.

Funder

Chonnam National University Hospital Biomedical Research Institute

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3