Abstract
Abstract
Background
It is rare that drains cannot be removed after surgery, however, this situation cannot be completely avoided, and is also hard to deal with. The main reason for a tethered drain is inadvertent suture fixation. At present, no effective way was published or widely accepted to locate the tethered drain.
Methods
Three cases of orthopedic trauma patients experienced unsuccessful removal of the drain after surgery. The ultrasound was used to locate the sutured site of the drain. Based on the sliding sign and vanishing point which can be detected by the ultrasound, the sutured site of the drain can be clearly identified. Finally, the suture was loosened through a small incision, and the drain was completely removed.
Results
The surgical procedure was very successful in all patients. The tethered drain was quickly and completely removed through a small incision with locating by ultrasound. Intravenous antibiotics were administered within 24 h after surgery, and no wound or deep infections occurred.
Conclusions
Ultrasound can be used to locate a tethered drain based on the sliding sign. This method can simplify the release procedure and achieve fast removal of the drain. Furthermore, it will help lower the risk of a retained drain and soft tissue complications.
Publisher
Springer Science and Business Media LLC
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献