Author:
Zheng Xiuli,Wu Mingli,Shi Huihui,Er Limian,Wang Kan,Cao Ying,Li Shengmian
Abstract
Abstract
Background
The aim of this study is to evaluate and compare the safety and efficacy of endoscopic mucosal resection with a cap (EMR-c) with those of endoscopic submucosal dissection (ESD) for rectal neuroendocrine tumors (R-NETs) ≤ 15 mm in diameter, and to analyze the risk factors of incomplete resection.
Methods
A total of 122 patients who underwent EMR-c or ESD for R-NETs at the Fourth Hospital of Hebei Medical University between February 2007 and December 2020 were invovled in this study. The clinical outcomes of two groups were compared and evaluated.
Results
A total of 122 patients with 128 R-NETs underwent endoscopic resection (EMR-c, 80; ESD, 48). In terms of duration of operation, EMR-c was significantly shorter than ESD (p < 0.001). Univariate analysis and multivariate analysis suggested that tumor diameter ≥ 8 mm was an independent risk factor for incomplete resection in patients with R-NETs in this study.
Conclusions
Both EMR-c and ESD were safe and effective treatments for R-NETs ≤ 15 mm in diameter. In addition, tumor diameter ≥ 8 mm was an independent risk factor for incomplete resection.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献