Author:
Wang Peng,Chen Cong,Liu Bo,Wang Xiaokang,Jiang Wei,Chu Xiangquan
Abstract
Abstract
Background
Migration of wires and pins within the heart is an uncommon complication. Intracardic migration of Kirschner wire can cause several complications.
Case presentation
A 55-year-old male patient was admitted to the emergency service with dyspnea, stabbing chest pain. The patient’s medical history showed that he had undergone a fixation operation using Kirschner wire and plate for treatment of the right sternoclavicular joint dislocation about 5 months prior. Chest computerized tomography revealed a metallic foreign body locating in the pericardium between the aorta and the right ventricle. There were not any serious complications occurred before operation due to the timely detection of potential risks. Removal of the wire was performed via median sternotomy under general anesthesia without cardiopulmonary bypass. The symptoms of dyspnea and chest pain were relieved after surgery, and the patient recovered without any complications.
Conclusion
The Kirschner wire should be used judiciously in amphiarthrosis in orthopedic surgery for the risk of breakage and migration. The possibility of intracardiac migration of wire should be considered when chest symptoms presenting after surgery with the Kirschner wire. Migrated wires must be removed immediately to prevent serious complications. Regular follow-up and early removal of fixation wires are recommended to prevent migration of wires.
Publisher
Springer Science and Business Media LLC
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献