Abstract
Abstract
Background
Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the compliance with tolerance limits given by the ISO 27020:2019. Different batches from each manufacturer were evaluated to determine whether or not they are different in size. In addition, the geometry of the slot walls was assessed.
Methods
360 stainless steel preadjusted orthodontic brackets of 12 different manufacturers were assessed. All brackets had a nominal slot size of 0.022 by 0.028 inches, belonged to the right upper central incisor, and were fabricated with the metal injection molding technique (MIM). For each manufacturer, three different manufacturing batches were evaluated. Brackets were coded using a single-blind design.
Results
All bracket systems in the study group except one displayed a statistically significant difference with the nominal declared value, although only four of the systems did not comply with the tolerance limits established by the ISO 27020:2019. In most of the systems, the slot height was oversized when compared to the nominal one. A significant interbatch variability was found in most of the evaluated systems. Most of the brackets walls were divergent.
Conclusions
The dimensional accuracy of commercially available metal brackets is not guaranteed. The respect for the norm should be enforced as well as the quality controls along the manufacturing process since orthodontic brackets are a precision medical device.
Publisher
Springer Science and Business Media LLC
Subject
Clinical Neurology,General Dentistry,Otorhinolaryngology
Reference29 articles.
1. Andrews LF. The straight-wire appliance. Explained and compared. J Clin Orthod. 1976;10:74–95.
2. Alavi S, Tajmirriahi F. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets. Dent Res J (Isfahan). 2016;13:440–5.
3. Banks P, Elton V, Jones Y, Rice P, Derwent S, Odondi L. The use of fixed appliances in the UK: a survey of specialist orthodontists. J Orthod. 2010;37:43–55.
4. Keim RG, Vogels DS, Vogels PB. 2020 JCO study of orthodontic diagnosis and treatment procedures Part1 results and trends. J Clin Orthod. 2020;54:581–610.
5. Streva AM, Cotrim-Ferreira FA, Garib DG, Carvalho PE. Are torque values of preadjusted brackets precise? J Appl Oral Sci. 2011;19:313–7.