Background
This prospective study aimed to evaluate the influence of the computer type (tablet or desktop) on accuracy and tracing time of cephalometric analyses.
Methods
Dental students used a web-based application specifically developed for this purpose to perform cephalometric analyses on tablet and desktop computers. Landmark locations and timestamps were exported to measure the accuracy, successful detection rate and tracing time. Reference landmarks were established by six experienced orthodontists. Statistical analysis included reliability assessment, descriptive statistics, and linear mixed effect models.
Results
Over a period of 8 semesters a total of 277 cephalometric analyses by 161 students were included. The interrater reliability of the orthodontists establishing the reference coordinates was excellent (ICC > 0.9). For the students, the mean landmark deviation was 2.05 mm and the successful detection rate for the clinically acceptable threshold of 2 mm suggested in the literature was 68.6%, with large variations among landmarks. No effect of the computer type on accuracy and tracing time of the cephalometric analyses could be found.
Conclusion
The use of tablet computers for cephalometric analyses can be recommended.
Funder
Open Access Publication Fund of the University of Münster
Universität Münster
Publisher
Springer Science and Business Media LLC