Eccentric Strength Assessment of Hamstring Muscles with New Technologies: a Systematic Review of Current Methods and Clinical Implications

Author:

Claudino João GustavoORCID,Cardoso Filho Carlos AlbertoORCID,Bittencourt Natália Franco NettoORCID,Gonçalves Luiz GilhermeORCID,Couto Crislaine RangelORCID,Quintão Roberto ChiariORCID,Reis Guilherme FialhoORCID,de Oliveira Júnior OtavianoORCID,Amadio Alberto CarlosORCID,Boullosa DanielORCID,Serrão Júlio CercaORCID

Abstract

AbstractBackgroundGiven the severe economic and performance implications of hamstring injuries, there are different attempts to identify their risk factors for subsequently developing injury prevention strategies to reduce the risk of these injuries. One of the strategies reported in the scientific literature is the application of interventions with eccentric exercises. To verify the effectiveness of these interventions, different eccentric strength measurements have been used with low-cost devices as alternatives to the widespread used isokinetic dynamometers and the technically limited handheld dynamometers. Therefore, the purpose of the present systematic review was to summarize the findings of the scientific literature related to the evaluation of eccentric strength of hamstring muscles with these new technologies.MethodsSystematic searches through the PubMed, Scopus, and Web of Science databases, from inception up to April 2020, were conducted for peer reviewed articles written in English, reporting eccentric strength of hamstrings assessed by devices, different to isokinetic and handheld dynamometers, in athletes.ResultsSeventeen studies were finally included in the review with 4 different devices used and 18 parameters identified. The pooled sample consisted of 2893 participants (97% male and 3% female: 22 ± 4 years). The parameters most used were peak force (highest and average), peak torque (average and highest), and between-limb imbalance (left-to-right limb ratio). There is inconsistency regarding the association between eccentric hamstrings strength and both injury risk and athletic performance. There is no standardized definition or standardization of the calculation of the used parameters.ConclusionsThe current evidence is insufficient to recommend a practical guide for sports professionals to use these new technologies in their daily routine, due to the need for standardized definitions and calculations. Furthermore, more studies with female athletes are warranted. Despite these limitations, the eccentric strength of hamstring muscles assessed by different devices may be recommended for monitoring the neuromuscular status of athletes.

Publisher

Springer Science and Business Media LLC

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3