Accuracy of the 6-Minute Walk Test for Assessing Functional Capacity in Patients With Heart Failure With Preserved Ejection Fraction and Other Chronic Cardiac Pathologies: Results of the ExIC-FEp Trial and a Meta-Analysis

Author:

Cavero-Redondo Iván,Saz-Lara Alicia,Bizzozero-Peroni Bruno,Núñez-Martínez Laura,Díaz-Goñi Valentina,Calero-Paniagua Ismael,Matínez-García Irene,Pascual-Morena Carlos

Abstract

Abstract Background Heart diseases, particularly heart failure, significantly impact patient quality of life and mortality rates. Functional capacity assessment is vital for predicting prognosis and risk in these patients. While the cardiopulmonary exercise test is considered the gold standard, the 6-minute walk test has emerged as a more accessible alternative. However, the screening accuracy and optimal cut-off points of the 6-minute walk test for detecting severely reduced functional capacity in cardiac pathologies, including heart failure with preserved ejection fraction, are unclear. The study aimed to analyse the diagnostic accuracy of the 6-minute walk test for detecting reduced functional capacity, defined as VO2max < 14 ml/kg/min, compared with the cardiopulmonary exercise test in participants with heart failure with preserved ejection fraction using data from the “Ejercicio en Insuficiencia Cardiaca con Fracción de Eyección Preservada” (ExIC-FEp) trial; and to compare these results with previous studies investigating the screening accuracy for assessing functional capacity of the 6-minute walk test in participants with other chronic cardiac pathologies through a meta-analysis. Results The ExIC-FEp trial involved 22 participants with heart failure with preserved ejection fraction, who were not treated with beta-blockers, using the cardiopulmonary exercise test, specifically VO2max, as the reference test. The 6-minute walk test had a sensitivity of 70%, a specificity of 80%, and an area under the curve of 76% in the ExIC-FEp trial. Five studies were included in the meta-analysis showing a sensitivity of 79%, a specificity of 78%, and an area under the curve of 85%. Conclusion In conclusion, the 6-minute walk test holds promise as a screening tool for assessing functional capacity in heart failure with preserved ejection fraction and chronic heart diseases, with a VO2max < 14 ml/kg/min as a reference point. It demonstrates moderate to good screening accuracy. However, the screening accuracy and optimal cut-off points of the 6-minute walk test for detecting severely reduced functional capacity, regardless of aetiology, are unclear. Trial Registration NCT05726474. Registered 16 February 2023, https://clinicaltrials.gov/study/NCT05726474.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3