Author:
Gao Fei,Li Huikai,Du Chen,Han Ke,Linghu Enqiang
Abstract
Abstract
Background
To explore the causes of endoscopic misdiagnosis of gastrointestinal cyst as solid lesion and the diagnostic value and limitations of EUS, guide clinicians to develop appropriate treatment strategies and improve the ability to identify SMT.
Methods
We enrolled patients diagnosed with gastrointestinal SMT between January 2001 and December 2021 who underwent endoscopic resection with postoperative pathological diagnosis of cyst. Age, sex, maximum lesion diameter, judge the texture of lesion, origin and echo are potential factors affecting the diagnostic accuracy of cysts.
Results
The diagnostic accuracy of EUS assessment 39.3% higher than that without EUS assessment (6.7%). The error rate was 60.7%, lower than that without EUS assessment (93.3%), suggesting that preoperative EUS assessment improved the diagnostic accuracy of gastrointestinal cyst (Fisher's accurate test, P = 0.033). The diagnostic accuracy of “judge the texture of lesion” was higher than that of no touch (P = 0.031). When the lesion size increased by 1 cm, the diagnostic accuracy decreased by about 21%. Hypoechoic lesions were less likely to be diagnosed correctly than anechoic lesions (P = 0.003).
Conclusions
The main cause of misdiagnosing gastrointestinal cyst as solid lesion is that no EUS assessment was performed before endoscopic resection or anechoic lesion was judged as hypoechoic lesion by preoperative EUS assessment.
Publisher
Springer Science and Business Media LLC
Subject
Gastroenterology,General Medicine